6.
Install Adaptec Storage Manager on the other servers.
7.
Copy the files from the diskette into the directory where
Adaptec Storage Manager is installed on the other servers.
- Adaptec Storage Manager can monitor status information returned
from certain enclosures. If there are any problems, information
such as fan status, power supply status, and temperature status
is collected and reported in the event viewer.
To monitor an enclosure, do the following:
1.
Write down the description displayed in the 'Product or
Model Number' field of the enclosure device information
panel.
2.
Exit Adaptec Storage Manager.
3.
Using a text editor, open the RaidDev.pps file.
is in the directory where Adaptec Storage Manager is
installed.
4.
Using the enclosure description from step 1, add a line to
the file.
the following:
3520EX10=true
5.
Save and close the file.
6.
Restart Adaptec Storage Manager.
--------------------------------------------------------------------
3. Adaptec Storage Manager Cautions and Notes
3.1 General Cautions
- While an array is being built or cleared, do not remove and
reinsert any drive from that array. Doing so may cause
unpredictable results for any of the controller's arrays.
- While a drive is being cleared, do not try to include it in a
new array. Doing so may cause unpredictable results.
- Do not move drives containing an array or volume from one
controller to another while the power is on. Doing so could
cause the loss of the array configuration or data, or both.
Instead, power off both affected controllers, move the drives,
and then restart.
- Do not run Adaptec Storage Manager concurrently with the CLI. Doing
so may cause unpredictable results.
3.2 General Notes
For example, if the description is 3520EX10, add
This file