Function
Range
AC Current
400.0 AAC
50/60 Hz
40.00 AAC
True RMS
DC Current
400.0 ADC
40.00 ADC
AC/DC A
400.00A
Current
4000.0A
AC Voltage
400.0 mVAC
50/60 Hz
4.000 VAC
True RMS
40.00 VAC
400.0 VAC
600 VAC
DC Voltage
400.00 mVDC
4.0000 VDC
40.000 VDC
400.00 VDC
600.0 VDC
Resistance
400.00
4.0000k
40.000k
400.00k
4.0000M
40.000M
Capacitance
400.00nF
4000.0nF
400.00µF
4000.0µF
40.000mF
Frequency
400.00Hz
(clamp)
Sensitivity: 5Arms minimum
GlobalTestSupply
www.
Accuracy
Resolution
(% of reading + digits)
0.1A
±(1.5% + 5 digits)
0.01A
0.1A
±(1.5% + 5 digits)
0.01A
0.01A
DC: ±(1.0% + 2 digits)
AC: ±(1.5% + 2 digits)
0.1A
0.1mV
±(1.0% + 20 digits)
0.001V
0.01V
±(2.0% + 5 digits)
0.1V
1V
0.01mV
0.0001V
±(0.1% + 6 digits)
0.001V
0.01V
0.1V
±(1.0% + 2 digits)
±(0.8% + 20 digits)
0.01
0.0001k
0.001k
±(0.8% + 4 digits)
0.01k
0.0001M
±(2.5% + 10 digits)
0.001M
0.01nF
±(5.0% + 40 digits)
0.1nF
±(3.0% + 10 digits)
0.01µF
±(3.5% + 10 digits)
0.1µF
±(5.0% + 10 digits)
0.001mF
0.01Hz
±(1.0% + 3 digits)
12