Download Print this page

Electrical Connections - GE Tetra Stick Installation Manual

Fluorescent box sign retrofit led lighting system

Advertisement

Tetra
Stick
®

Electrical Connections

Single Tetra Stick Installation
Power Supply
Connect the red wire (+) of the Tetra Stick to the red wire (+) of the power supply. Connect the black wire (-) of the Tetra Stick to
1
the black or blue wire (-) of the power supply. Seal all connections that could be exposed to water with electrical grade RTV silicone
Multiple Tetra Stick Installation
Add up total number of Tetra Sticks to determine the
1
appropriate number of 24VDC Class 2 Tetra LED drivers
to use based on the Specifications Charts for Tetra
Stick chosen (see pages 4-5).
AC line
Connect Tetra Stick using twist-on wire connectors or in-line (IDC) connectors. Join black wires together and red wires
3
together. Seal all connections that could be exposed to water with electrical grade RTV silicone.
NOTE: Make sure not to exceed LED driver power limits (see Step 1). Drawing above is for reference only; your lighting
layout may differ.
NOTE: All drivers except GEPS24-180U and GEPS24-300U must be enclosed or provided with a GEPSJB60 LED driver
extended enclosure.
NOTE: Refer to Power Supply Installation Guide for AC driver installation.
+
+
GEPS24-180
Red (+)
Red (+)
Power supply
Red (+)
Red (+)
Power supply
Connect the red wire (+) of the Tetra Stick to the red
2
wire (+) of the power supply. Connect the black wire (-)
of the Tetra Stick to the black or blue wire (-) of the
power supply.
3
Installation Guide
Black or blue (-)
Black (-)
To Tetra Sticks
Black or blue (-)
Black (-)
To Tetra Sticks

Advertisement

loading