Unlocking Procedure; Spare Parts; Disposal - Askoll ENERGY SAVING ES2 Installation And Operation Instructions Manual

Hide thumbs Also See for ENERGY SAVING ES2:
Table of Contents

Advertisement

ENERGY SAVING
Should you fail to eliminate the cause of the malfunction, refer to the Distributor or nearest Service
Center.

13.2 Unlocking procedure

A red light in the LED indicates a locking.
Turn the selector to the position max, disconnect and connect power supply to start the automatic
release process.
The circulator operates 100 attempts to restart (process lasts approximately 15 minutes).
Every restart is signalled by a short flash of LED light. If the locking is not removed through the
automatic release process after 100 attempts to restart the circulator, it goes into standby and the
LED remains red. In this case follow the manual procedure described in the next steps:
during any attempt, the red LED light keeps blinking; after that the circulator tries again to start. If
the locking is not removed through the automatic release process (the warning light returns to be
red), it is necessary to perform the manual proceeding described in the next steps:
Disconnect power supply - the warning light switches off.
Close the interception organs upstream and downstream of the circulator and let it cool.
Disassemble the motor and clean the impeller.
1. Disconnect power supply - the warning light switches off.
2. Close both isolating valves and allow cooling. If there are no shut-off devices, drain the
system so that the fluid level is beneath that of the circulator.
3. Carefully pull the rotor/impeller
4. Remove impurities and deposits with appropriate agents.
5. Reinsert the rotor/impeller
6. Set the selector on the wished position.
7. Connect power supply.
If the circulator doesn't run → 13 Faults, causes and remedies.
With high fluid temperatures and pressures there is the risk of burnings.
Hazard of scalding by simple contact.

14 Spare parts

Spare parts are ordered via local specialist retailers.
Should you need to order any spare parts, always provide all rating data of the circulator.

15 Disposal

The correct disposal and recycling of this product will prevent damage to the environment and risks
to human health.
1. Use public or private disposal organisations when disposing of all or part of the product.
2. For information about proper disposal, it is necessary to ask to the city administration, the
authorized office or the retailers of the product.
Reserved right of modification
Spare parts