iNode Energy Meter – instruction manual
ELSAT s.c.
After selecting the Data tab the following window will appear:
Data in the memory are cyclically saved, i.e. when it is full, the oldest data is deleted. The memory
has a capacity of approx. 8192 records - standard version or 7680 records, Long Range version.
One record is a time stamp and each entry with iNode Energy Meter. The data is compressed, i.e.
if the instantaneous (in a given minute) energy consumption differs from that in the previous period
by more than +/- 1 then the record is saved. The total counter of counted pulses can be reset by
removing the battery from the device for a long time (minimum 60 seconds)
There are two options that can be selected when reading data:
Read data from memory iNode: reads data from memory.
Delete data memory in iNode: erase data in memory, RTC setting and enable data logging.
Pressing the Execute button will save the modified settings to the device.