NOTICE Thank you for choosing an Award range hood. Please read the instruction manual carefully before use. The installation work must be undertaken by a qualified and competent person. The manufacturer disclaims all liability for any damage or injury caused as a result of not following instructions for installation contained in the following text.
(2) INSTALLATION The range hood should be placed at a distance of 65~75cm above the cooking plane for best effect. See pic 1. Install the hook on a suitable place once the installation height is fixed, and keep it in line. The fixed position of the inside chimney bracket is the place of chimney.
Page 5
If you do not have an outlet to the outside, the ducting is not required and the installation is similar to the one shown in the “INSTALLATION (VENT OUTSIDE)” section Carbon filter-not supplied Activated carbon filter can be used to trap odors. Normally the activated carbon filter should be changed every 3 to 6 months according to your cooking habits.
(3) NOTICE OF INSTALLATION The following rules must be strictly followed to obtain optimal air extraction: • Keep flexible tube duct short and straight. • Do not reduce the size or restrict the flexible tube duct. • When using the flexible tube duct always install the pipe pulled taut to minimize pressure loss.
SAFETY WARNING Do not try to use the range hood without the grease filters or if the filters are excessively greasy! Do not install above a gas hob with a high level grill. Do not leave frying pans unattended during use because overheated fats or oil smight catch fire.
Warning: Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards. Warning: Before obtaining access to terminals, all supply circuits must be disconnected. Always put lids on pots and pans when cooking on a hob. ...
Page 9
When the range hood and appliances supplied with energy other than electricity are simultaneously in operation, the negative pressure in the room must not exceed 4 Pa (4 x 10-5 bar). Warning: Danger of fire: do not store items on the cooking surfaces. ...
Page 10
(5) USE Electronic button There are five buttons: (Low), (Mid), (High), (Lamp), (Power).See picture above. After connecting to power, indicator light will be lit, and the range hood will enter standby mode. The indicator light will turn off automatically if no function is selected.
Page 11
Low speed, mid speed and high speed cannot work at the same time. When range hood is on high speed, press low speed, it will turn to low speed at once; when it is in low speed, press middle speed, it will turn to middle speed immediately, and so on.
(7) TROUBLE SHOOTING Fault Cause Solution The flue blocked Clear the blockage The capacitor damaged Replace capacitor Light on, but motor does not work The motor jammed bearing Replace motor damaged Beside the above mentioned, check the following: Light damaged Replace lights Light does not work, motor does not work...