SFC-199 - Fuel Conversion to Propane
(NG to LP) Kit P-844
 
Note
If converting from propane to natural gas, order the natural gas conversion parts kit (IBC Part # P-845) from 
your authorized IBC distributor.
Use the propane gas conversion parts kit if the fuel source at the site uses propane and the appliance has been set up 
(factory fire-tested) to operate with natural gas. Check the rating plate to see which fuel source the particular appliance 
has been set up with.
Using this conversion kit, a qualified technician will need to:
 1.  Perform a fuel conversion.
 2.  Perform a combustion test.
 3.  Fill in the information required on the fuel conversion labels, and affix them to the appliance after the conversion is 
completed.
Warning
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's 
instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in 
these instructions is not followed exactly, a fire, an explosion or production of carbon monoxide may result 
causing property damage, personal injury or loss of life. 
The qualified service agency is responsible for the proper installation of this kit. The installation is not proper 
and complete until the operation of the converted appliance is checked as specified in the manufacturer's 
instructions supplied with the kit.
The appliance will automatically de-rate the maximum input at a rate of approximately 2% per 1,000' above 4,500'. The 
gas valve's zero-governor will ensure that the gas-air mixture is not affected at altitude.
Included with the conversion kit:
1 x Orifice - marked 535 - IBC Part # 180-174
1 x O-ring - IBC Part # 150-175
1 x Rating Plate Fuel Overlay - IBC Part # 080-272A
1 x Gas Valve Conversion Label - IBC Part # 080-107B
1 x Installer Identification Label - IBC Part # 080-211A
120-260E
| 1

Advertisement

loading

Summary of Contents for IBC SFC-199

  • Page 1 SFC-199 - Fuel Conversion to Propane (NG to LP) Kit P-844   Note If converting from propane to natural gas, order the natural gas conversion parts kit (IBC Part # P-845) from  your authorized IBC distributor. Use the propane gas conversion parts kit if the fuel source at the site uses propane and the appliance has been set up  (factory fire-tested) to operate with natural gas. Check the rating plate to see which fuel source the particular appliance  has been set up with. Using this conversion kit, a qualified technician will need to:  1.  Perform a fuel conversion.  2.  Perform a combustion test.  3.  Fill in the information required on the fuel conversion labels, and affix them to the appliance after the conversion is  completed. Warning This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s  instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in  these instructions is not followed exactly, a fire, an explosion or production of carbon monoxide may result  causing property damage, personal injury or loss of life.  The qualified service agency is responsible for the proper installation of this kit. The installation is not proper  and complete until the operation of the converted appliance is checked as specified in the manufacturer’s  instructions supplied with the kit. The appliance will automatically de-rate the maximum input at a rate of approximately 2% per 1,000’ above 4,500’. The  gas valve's zero-governor will ensure that the gas-air mixture is not affected at altitude. Included with the conversion kit: 1 x Orifice - marked 535 - IBC Part # 180-174 1 x O-ring - IBC Part # 150-175 1 x Rating Plate Fuel Overlay - IBC Part # 080-272A 1 x Gas Valve Conversion Label - IBC Part # 080-107B...
  • Page 2 Combustion Test Target Ranges Figure: Gas valve and fan The Low Fire (zero-offset) valve adjustment cap on the gas valve has been factory set. Do not adjust this screw in the field  unless indicated   i n these instructions.  After converting the appliance to propane, a combustion (CO ) reading must be taken by a qualified technician using  properly functioning and calibrated combustion analyzing equipment and the results compared to the values in Table 1. Value (%) at High Fire with front Value (%) at Low Fire with front Propane cover open cover open Max. CO  value 11.5% Value at High Fire Minus - 0.3% Min. CO  value 9.5%...
  • Page 3: Fuel Conversion Instructions

    Table 2 - Propane Orifice Chart To perform a fuel conversion:  1.  Turn off the gas supply at the gas shut-off valve.  2.  Disconnect the electrical power.  3.  Disconnect the nut at the gas valve outlet (top of the gas valve), and remove the O-ring and orifice.  4.  Insert the correct orifice into the O-ring, and re-install into the nut at the gas valve outlet (top of the gas valve),  and then tighten the nut.  5.  Restore the gas supply by opening the gas control valve.  6.  Test for leaks by using an approved leak detection solution on all joints.  7.  Power on the   a ppliance. Now, carefully follow the procedures on Combustion Testing and Adjustment. SFC-199 - Fuel Conversion to Propane (NG to LP) Kit P-844...
  • Page 4 Combustion testing and adjustment Danger A combustion test checks that the gas valve is operating properly in the field. To perform a combustion test, you  must be a qualified, trained and licensed gas fitter. Making adjustments to the gas valve without a properly calibrated gas combustion analyzer and by people who  are not trained and experienced in its use is forbidden. Failure to use an analyzer can result in an immediate  hazard. Model Number High Fire Input SFC-199 125 MBH (on a heavy load, only  DHW   p rovides full input of 199  BTUs)   Table 3 - Rated input of a converted appliance Normal ignition system sequence of operation: The appliance's control, upon a call for DHW, turns on the combustion fan for a short pre-purge, then energizes the spark  electrode and gas valve for a 5-second trial for ignition. If the burner does not light, the process is repeated until the burner lights and flame is detected. After 4 unsuccessful trials  for ignition, the appliance locks out and will need to be manually reset by pressing the Return Arrow   button.  To perform a combustion test and adjustment:  1. ...
  • Page 5 . If the target cannot be met, even after a half turn, contact the  factory.   c.  When finished, replace the Low Fire cap, and leave the manual mode by pressing + AND -  simultaneously.  7.  Switch off the appliance by pressing the space above the white dot.   8.  Turn off the gas at the appliance's gas shut-off valve.  9.  Remove the flue gas analyzer from the test port, and reinstall the test port cap.   10.  Remove the gas pressure manometer from the gas valve, and close the test port.  11.  Turn on the gas at the appliance’s gas shut-off valve.  12.  Ensure there are no gas leaks before reinstalling the front cover.   13.  Turn on the appliance by pressing the space above the white dot. Completing and Affixing the Conversion Labels  1.  Fill in the conversion labels (included in the kit) associated with the new fuel type.  2.  Place the conversion labels onto the appliance as indicated on the last page. SFC-199 - Fuel Conversion to Propane (NG to LP) Kit P-844...
  • Page 6 Clocking the Meter (for Natural Gas only)  1.  Turn off all other appliances and pilots.  2.  Turn on the appliance and set the appliance to high fire.  3.  Ensure the appliance has a large load to heat, so that the appliance will not shut off.  4.  With a Stop-Watch, record the number of seconds for the smallest dial to make 1 full revolution.  5.  CFH = (3600 x Dial Size) / Seconds.  6.  CFH x 1000 (check local Btu content) = Input Btu’s.   Note For 2 PSI meters multiply CFH x 1.097 For Metric meters multiply CFH x 35.3 For 2 PSI metric meters multiply CFH x 1.097 x 35.3 For Altitude above 4,500' deduct 2% per 1,000’ of altitude from the Input Btu’s.
  • Page 7 Where to Place Conversion Labels on the appliance SFC-199 - Fuel Conversion to Propane (NG to LP) Kit P-844...