Download Print this page

Fuel Conversion Instructions - IBC SFC-199 Fuel Conversion Instructions

Fuel conversion to propane (ng to lp) kit

Advertisement

Fuel Conversion Instructions

You must be a qualified technician to perform a fuel conversion. 
Model Number
SFC-199
Table 2
- Propane Orifice Chart
To perform a fuel conversion:
 1.  Turn off the gas supply at the gas shut-off valve.
 2.  Disconnect the electrical power.
 3.  Disconnect the nut at the gas valve outlet (top of the gas valve), and remove the O-ring and orifice.
 4.  Insert the correct orifice into the O-ring, and re-install into the nut at the gas valve outlet (top of the gas valve), 
and then tighten the nut.
 5.  Restore the gas supply by opening the gas control valve.
 6.  Test for leaks by using an approved leak detection solution on all joints.
 7.  Power on the   a ppliance.
Now, carefully follow the procedures on Combustion Testing and Adjustment.
SFC-199 - Fuel Conversion to Propane (NG to LP) Kit P-844
Orifice Size
535