Assembling the shore power
Connector
7Step 1:
Remove approx .75" (2 cm) of the outer jacket. Remove approx. .3"
(8 mm) of the inner wires insulation. Tin the stranded copper ends.
7Step 2:
Remove the security cap using a screw driver.
7Step 3:
Pull the conductor through the pre-latched strain relief housing.
7Step 4:
Open the clamp with a screwdriver and insert the first wire up to the stop. Repeat
this step for all three wires.
7Step 5:
Latch the connector on to the strain relief housing.
7Step 6:
Snap together the upper and lower parts of the strain relief housing and
tighten the screw as shown.
Recommended Recommended
DC cable size AC cable size
12V10A : 2.5 mm
2
12V15A : 2.5 mm
2
12V25A : 4.0mm
2
12V40A : 6.0 mm
12V60A : 14.0 mm
cables : 1.5 m / 4.9 feet max
Cable type: according to local regulations
/ 12 AWG 12V10A : 3 x 0.75 mm
/ 12 AWG 12V15A : 3 x 0.75 mm
/ 10 AWG 12V25A : 3 x 1.5 mm
/ 8 AWG 12V40A : 3 x 1.5 mm
2
/ 6 AWG 12V60A : 3 x 2.5 mm
2
cables : 3 m / 9.8 feet max
/ 16 AWG
2
/ 16 AWG
2
/ 14 AWG
2
/ 14 AWG
2
/ 12 AWG
2