4.0 FLOW CHARACTERISTICS

At each fl ow setting, the nozzle is set to a predetermined fi xed orifi ce. Relationship of fl ow and nozzle pressure at each setting is
shown in fi gures 4A and 4B.
FLOW (LPM)
80
140
120
100
80
60
40
20
0
0
20
40
FLOW (GPM)
20, 60 GPM BUBBLE CUP

4.1 TRAJECTORY CHART

GPM
CURVE
FLOW
A
20
B
60
C
95
These trajectories, reach, and reaction numbers are provided for reference. All data based on 30 degree nozzle discharge angle, in
straight stream setting. Actual trajectories, reach, and reactions may vary with wind conditions, discharge angle (elevation), stream
setting, fl uid type, fl uid/water ratio, fl uid temperature, pressure, and fl ow at the nozzle. It is the operator's responsibility to determine
that the system provides adequate reach for the intended purpose.
©Copyright Task Force Tips LLC 2002 - 2019
160
240
320
60
80
100
Figure 4A
100 PSI RC BUBBLE CUP NOZZLE
PRESSURE
LBS
PSI
REACTION
100
10
100
30
100
48
80
140
9
120
8
7
100
6
80
5
4
60
3
40
2
20
1
0
0
20
CURVE
A
B
C
Trajectory chart
Figure 4.1
5
FLOW (LPM)
160
240
320
40
60
80
FLOW (GPM)
20, 95 GPM BUBBLE CUP
Figure 4B
LPM
PRESSURE
FLOW
BAR
REACTION
75
6.9
227
6.9
360
6.9
LKB-200 July 29, 2018 Rev01
9
8
7
6
5
4
3
2
1
100
KGf
4.5
13.6
21.7

Advertisement