PARAMETER PAGE

From a winch base screen, the PARAM PAGE touchbutton opens the parameter page for that winch.
Touchscreen display winch parameter page
keypad will appear. Use this to key in the appropriate user name, then press the ENTER key on the keypad.
Follow the same procedure in the password field to enter the password. When these values are entered, the
display returns to the winch parameter page. Once the access privileges have been activated, touching an
appropriate entry field will bring up a keypad to permit a new value to be entered.
The LOG OFF button is used to log the user off after changing parameters. The user will automatically log off
after five minutes, to prevent unauthorized access to parameters.
User-level privileges permit changes to the following items, indicated by a (U) following their descriptors:
SUL: Height of the batten above the reference point at the Soft Upper Limit
SLL: Height of the batten above the reference point at the Soft Lower Limit
DFT SPD: The default speed that is loaded into the SPEED field when the base screen is opened, or when the
DFLT SPD touchbutton is pushed.
ACC: Time (in milliseconds) for the winch to accelerate to full speed. As an example, with a setting of 3000 the
winch will reach full speed in 3 seconds. If the selected winch speed is less than full speed, it will require
proportionately less time to reach that speed.
DEC: Time (in milliseconds) for the winch to decelerate from full speed to a stop. A setting of 3000 will cause the
winch to decelerate from full speed to a stop in 3 seconds. If the winch is traveling at less than full speed, it will
require proportionately less time to decelerate to a stop.
Design, Manufacture and Installation of Theatrical Equipment Worldwide
(315) 451-3440
Fax (315) 451-1766
Rev 1: February 13, 2007
SCENECONTROL 100 OPERATING INSTRUCTIONS
The parameter page displays certain winch
values, and provides a place where an
authorized user can manipulate them. The
BASE PAGE jump button at the bottom left
of the screen will return to the winch base
screen.
Values
displayed
password-protected. Certain crucial values
are protected by the system level password.
These are indicated by and (S) following
their descriptor.
Other values have the
indication (U) following their descriptor.
These values may be adjusted by an
operator logged in with the User level
username and password. If an operator is
not logged in, touching a numeric entry field
will pop up the user name and password
entry fields. To enter the user name, touch
the user name field; an alphanumeric
www.jrclancy.com
PAGE 9
on
this
page
are

Advertisement