Technical Specifications; Connections And Supply Voltage; Wireless; Environment - Siemens SIMATIC RTLS PCB OEM PULSE Manual

Localization systems
Hide thumbs Also See for SIMATIC RTLS PCB OEM PULSE:
Table of Contents

Advertisement

2 Technical specifications

2.1 Connections and supply voltage

Connections and supply voltage
Voltage
Energy intake

2.2 Wireless

Wireless PULSE (localization)
Wireless process
Transmission speed
Frequency range
Bandwidth
Transmit power
Antenna
Range

2.3 Environment

Environment
PCB dimensions
Antenna dimensions
Weight
Temperature range
Method of securing
8
3.3 V DC (±100 mV)
Max. 0.3 A
IEEE 802.15.4-2011 UWB
850 Kbps
The following frequency bands are supported:
4000 MHz
6500 MHz
500 MHz
0.037 mW
Connected via antenna cable
Inside maximum 90 m (typical 60 m),
Outside maximum 1000 m (typical 500 m)
44 x 24 x 7.5 mm
38 x 20 x 3 mm
Approx. 10 g
0 to +50 ℃
PCB: 3 screws, Ø 1.7 mm
Antenna: provided by customer
SIMATIC RTLS PCB OEM PULSE
Manual, 10/2018, C79000-G8976-C552-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

6gt2700-8af03

Table of Contents