System 3
2-tank solar system with pump logic
The controller compares the temperature at sensor
S1 to the temperatures at sensors S2 and S4. If the
measured temperature differences are higher than
the adjusted switch-on temperature differences, the
pump (R1 and/or R2) will be activated and the cor-
responding tank will be loaded up to the adjusted
maximum temperature at most.
Sensor/
Designation
Description
terminal
S1
TCOL
Temperature collector
S2
TST1B
Temperature tank 1 bottom
S3
Optional sensor for measure-
ment purposes or options
S4
TST2B
Temperature tank 2 bottom
S5
Optional sensor for measure-
ment purposes or options
V40
Relay
Description
R1
Solar pump tank 1
R2
Solar pump tank 2
R3
optional:
Thermal disinfection
R4
Parallel relay
Heat dump