6.9.3
Terminal strip
Connections:
A = Ground heating element DC
B = Plus heating element DC
C = Ground electronics
D = Plus electronics
For operation, it is compulsory to provide the device with a permanent 12V
DC connection at terminals C/D (permanent voltage supply for the functio-
nal electronics).
6.9.4
Wiring diagram
Reed contacts
(sensor switching)
lighting DC
permanently
connection DC
C
D
on the appliance
-
+
C D
on the vehicle
ionisation
plug
ignition
plug
ignition unit
Ground
gas burner
heating element DC
valve
temp. sensor
27
-
+
A B
Connections:
A = Ground heating element DC
B = Plus heating element DC
C = Ground electronics
D = Plus electronics
Colours:
schwarz = black
violett = violet
braun = brown
weiss = white
grün = green
gelb = yellow
rot = red
B
A
heating element AC
mains
Ground
connection