elsner elektronik AQS/TH PF Technical Specifications And Installation Instructions

elsner elektronik AQS/TH PF Technical Specifications And Installation Instructions

Indoor sensor and ventilation control

Advertisement

Quick Links

EN
AQS/TH PF
Indoor Sensor and Ventilation Control
Technical specifications and installation instructions
Item number 40115
Elsner Elektronik GmbH Control and Automation Engineering
Sohlengrund 16
75395 Ostelsheim
Germany
Phone +49 (0) 70 33 / 30 945-0 info@elsner-elektronik.de
Fax
+49 (0) 70 33 / 30 945-20 www.elsner-elektronik.de
Technical support: +49 (0) 70 33 / 30 945-250

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AQS/TH PF and is the answer not in the manual?

Questions and answers

Summary of Contents for elsner elektronik AQS/TH PF

  • Page 1 AQS/TH PF Indoor Sensor and Ventilation Control Technical specifications and installation instructions Item number 40115 Elsner Elektronik GmbH Control and Automation Engineering Sohlengrund 16 75395 Ostelsheim Phone +49 (0) 70 33 / 30 945-0 info@elsner-elektronik.de Germany +49 (0) 70 33 / 30 945-20 www.elsner-elektronik.de...
  • Page 2: Technical Data

    (rain detector or similar) takes precedence. The housing fits into standard 55 mm switching programmes and is available in two different colours. The AQS/TH PF is equipped with two buttons for manual control of the respective window/ventilator and for adjusting the device. The display shows current measured values and mode and guides through the set-up menus.
  • Page 3 When measuring temperature, the self-heating of the device is considered by the electronics. The heating is compensated by reducing the measured temperture by the self-heating of 0.7°C. The indicated indoor temperature measured value approches the Ventilation Control AQS/TH PF • Version: 31.01.2017 • Technical changes and errors excepted.
  • Page 4: Installation And Start-Up

    Elsner Elektronik is not liable for any changes in norms and standards which may occur after publication of these operating instructions.
  • Page 5 2.3. Sensor connection and design 2.3.1. Housing Fig. 1 Base plate Catches Openings for air circulation CLOSE/- button CLOSE/- LED (recessed) OPEN/- LED (recessed) OPEN/- button Openings for air circulation (LOWER) Ventilation Control AQS/TH PF • Version: 31.01.2017 • Technical changes and errors excepted.
  • Page 6 Supply voltage for output 1+2 black Input 2 (OPEN/+) yellow Input 1 (CLOSE/-) black Supply voltage for input 1+2 white Operating voltage GND black Operating voltage +24 V Ventilation Control AQS/TH PF • Version: 31.01.2017 • Technical changes and errors excepted.
  • Page 7 Installation and start-up 2.3.3. Wiring diagram Window Fig. 4: With relays Ventilation Control AQS/TH PF • Version: 31.01.2017 • Technical changes and errors excepted.
  • Page 8 Installation and start-up 2.3.4. Wiring diagram Ventilation Units Fig. 5 With Relays Ventilation Control AQS/TH PF • Version: 31.01.2017 • Technical changes and errors excepted.
  • Page 9: Sensor Assembly

    2.5. Notes on mounting and commissioning Never expose the device to water (e.g. rain) or dust. This can damage the electronics. You must not exceed a relative humidity of 95%. Avoid condensation. Ventilation Control AQS/TH PF • Version: 31.01.2017 • Technical changes and errors excepted.