4.0

OPERATING CONDITIONS

4.1

ENERGY RELATIONSHIPS

At 24V input, 600V output, the unit delivers a minimum of 20 joules per second to
the discharge capacitor. Figure 3.1 shows typical charge rate values vs output
voltage for four different DC inputs.

Figure 3. PS-1120 Typical Charge Rate Curves.

The energy per discharge is given by the expression:
J = Discharge energy
C = Discharge capacitance
V = Output voltage
Power is determined by P= J x Flashrate
Long-term (1 minute or more) average
power must be limited to 20 watts.
Therefore, the sum total of the
accumulated energy discharges
(Joules) divided by the operating
period (seconds) must be ≤ 20 watts.
The flashtube may be fired any time
after the charge time (see Fig. 4).
FF0091
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
PS-1120 POWER SUPPLY OPERATION MANUAL
OUTPUT
VOLTAGE (V)
t=0
TUBE
FIRES
0
HOLD-OFF
200us
±30us

Figure 4. Output Voltage vs. Time

5
CHARGE
TIME
TUBE
FIRES
t=8.0ms
TIME(t)
0
1/f
UM0024 Rev L