Specifications; Table 1. Electrical Input; Table 2. Electrical Output (Discharge); Table 3. Electrical Output (Trigger) - PerkinElmer PS-1120 Operation Manual

Table of Contents

Advertisement

A B C R D
2.0

SPECIFICATIONS

Voltage
Current
Trigger
V
(V
/V
=100)
ref
0
ref
Voltage (V
)
o
Charge Rate, min.
Power Output
Line Regulation
Ripple
Internal Discharge Cap
Trigger Voltage
Trigger Capacitor
Max. Pulse Rate
Recharge Delay
Output Connector
Enclosure
Dimensions
Weight
Operating Temperature
Storage Temperature
FF0091
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
PS-1120 POWER SUPPLY OPERATION MANUAL

Table 1. Electrical Input

15-28V DC
Less than 1.2A DC @ 24V DC, 20W output
Optically isolated; 20-50mA peak input; 10-20µs pulse
width; leading edge trigger. Int. series resistor = 150Ω.
4-10V DC

Table 2. Electrical Output (Discharge)

400-1KV DC ±2%
15 J/sec (15V input, 600V output)
20 J/sec (24V input, 600V output)
20 watts max.
±1%
0.5%, with 0.1µF, 600V charge (P-P
PS-1120-1
0.1µF ±10%

Table 3. Electrical Output (Trigger)

175±15V
0.1µF
60/J where energy per flash, J = ½ capacitance x voltage
2
(J = ½ CV
). Do not exceed 1KHz
200µsec (typical)

Table 4. Mechanical Properties

9 pin "D" subminiature; mating connector supplied
Wago Terminal Strip
Metal Case
5.85"L x 3.63"W x 1.70"H
22.5 oz. (635g)

Table 5. Environmental Specifications

+32°F to +104°F (0°C to +40°C)
-40°F to +194°F (-40°C to +90°C)
3
)
max
PS-1120-2
PS-1120-3
0.25µF ±10%
0.5µF ±10%
2
UM0024 Rev L