Site Considerations

rates with your existing equipment, these considerations may help you isolate the cause of failures and prevent
future problems.
Site Considerations
Considering the following helps you plan an acceptable operating environment for the chassis, and avoid
environmentally-caused equipment failures.
• Electrical equipment generates heat. Ambient air temperature might not be adequate to cool equipment
• Ensure that the chassis cover is secure. The chassis is designed to allow cooling air to flow effectively
• Always follow ESD-prevention procedures to avoid damage to equipment. Damage from static discharge

Power Supply Considerations

See
Hardware Specifications, on page 12
When installing the chassis, consider the following:
• Check the power at the site before installing the chassis to ensure that it is free of spikes and noise. Install
• Install proper grounding for the site to avoid damage from lightning and power surges.
• The chassis does not have a user-selectable operating range. Refer to the label on the chassis for the
• Several styles of AC-input power supply cords are available for the chassis; make sure that you have the
• If you are using dual redundant (1+1) power supplies, we recommend that you use independent electrical
• Install an uninterruptible power source for your site, if possible.

Rack Configuration Considerations

See
Rack-Mount the Chassis, on page 27
Consider the following when planning a rack configuration:
• If you are mounting a chassis in an open rack, make sure that the rack frame does not block the intake
Cisco Firepower 1100 Series Hardware Installation Guide
24
to acceptable operating temperatures without adequate circulation. Make sure that the room in which
you operate your system has adequate air circulation.
within it. An open chassis allows air leaks, which may interrupt and redirect the flow of cooling air from
the internal components.
can cause immediate or intermittent equipment failure.
a power conditioner, if necessary, to ensure proper voltages and power levels in the appliance-input
voltage.
correct appliance input-power requirement.
correct style for your site.
circuits for each power supply.
or exhaust ports.
for more detailed information about the power supply in the chassis.
for the procedure for rack-mounting the chassis.