Hide thumbs Also See for ACCU-CAL 50:

Advertisement

sales@artisantg.com
artisantg.com
(217) 352-9330 |
|
Click HERE
Find the Dymax Accu-Cal 50 at our website:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACCU-CAL 50 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for dymax ACCU-CAL 50

  • Page 1 (217) 352-9330 | Click HERE Find the Dymax Accu-Cal 50 at our website:...
  • Page 2 Dymax ACCU-CAL™ 50 User Guide UV Radiometer Instructions for Safe Use  Setup and Operation  Maintenance  Ordering Spare Parts and Accessories  ACCU-CAL™ 50 for Flood Lamps (PN 39561) ACCU-CAL™ 50 for Spot Lamps (PN 39560)
  • Page 3 System designs enable stand-alone configuration or integration into your existing assembly line. Please note that most dispensing and curing system applications are unique. Dymax does not warrant the fitness of the product for the intended application. Any warranty applicable to the product, its application and use is strictly limited to that contained in the Dymax standard Conditions of Sale.
  • Page 4: Table Of Contents

    Dymax ACCU-CAL™ 50 Radiometer User Guide Contents Introduction ..........................4 Safety ............................4 General Safety ..............................4 Safety ................................5 Sécurité ................................5 Sicherheitshinweise ............................5 Product Overview ........................6 Description of the ACCU-CAL™ 50 Radiometer ..................... 6 Installation ..........................6 Unpacking and Inspecting Your Shipment ..................... 6 Parts Included in the Spot Configuration .......................
  • Page 5: Introduction

    Dymax ACCU-CAL™ 50 Radiometer User Guide Introduction The enclosed ACCU-CAL™ 50 UV Radiometer was developed and manufactured by the Dymax team, driven by a desire to best serve your needs. Before shipping, your ACCU-CAL™ 50 Radiometer was calibrated and tested against standard UV light sources to ensure accurate performance.
  • Page 6: Safety

    Dymax ACCU-CAL™ 50 Radiometer User Guide Safety The ACCU-CAL™ 50 Radiometer is designed to be used in conjunction with Dymax UV light-curing equipment that is properly set up, with components correctly connected, and operated in accordance with relevant instructions. Safety Recommendations: When working with UV light sources, use the goggles provided, or a face shield approved for UV protection to protect your eyes.
  • Page 7: Product Overview

    Open the box and check for equipment damage. If parts are damaged, notify the shipper and submit a claim for the damaged parts. Contact Dymax so that new parts can be shipped to you immediately. Check that the parts included in your order match those listed below. If parts are missing, contact your local Dymax representative or Dymax Customer Support to resolve the problem.
  • Page 8: Operation

    Dymax ACCU-CAL™ 50 Radiometer User Guide Figure 1. Spot Radiometer (PN39560) Figure 2. Flood Radiometer (PN39561) Operation 1. The ACCU-CAL™ 50 Radiometer may be used to measure UV intensity from Flood Lamps or UV intensity from the end of a 3-mm, 5-mm, or 8-mm lightguide used with a Spot Lamp. For Flood Lamp use, attach the Detector to the Radiometer as shown in Figure 3.
  • Page 9 Dymax ACCU-CAL™ 50 Radiometer User Guide Figure 5. Adapter Installation 4. Attach the Lightguide Adapter to the Spot Lamp Lightguide by inserting the Lightguide into the Lightguide Adapter until it bottoms out. Tighten the set screw when the Lightguide is installed.
  • Page 10: Maintenance

    The ACCU-CAL™ 50 was designed to operate with minimum maintenance. Follow the schedule below to assure top unit performance. • Calibrate the instrument at least annually. Calibration service is available through Dymax Customer Service or Dymax Product Repair. • Change the batteries when a low battery warning is received. The ACCU-CAL™ 50 uses two AA-type batteries.
  • Page 11: Specifications

    Dymax ACCU-CAL™ 50 Radiometer User Guide Specifications Property Specification Power Two AA size batteries LCD Graphic Display 97x 32 Pixel Display Display area: 0.56 in x 1.41 in (14.3 mm x 35.8 mm) Detector Interface 9-Pin MDSM9 socket, 4 inputs...
  • Page 12: Warranty

    Unauthorized repair, modification, or improper use of equipment may void your warranty benefits. The use of aftermarket replacement parts not supplied or approved by Dymax Corporation will void any effective warranties and may result in damage to the equipment.
  • Page 13 Please note that most dispensing and curing system applications are unique. Dymax does not warrant the fitness of the product for the intended application. Any warranty applicable to the product, its application and use is strictly limited to that contained in Dymax’s standard Conditions of Sale. Dymax recommends that any intended application be evaluated and tested by the user to insure that desired performance criteria are satisfied. Dymax is willing to assist users in their performance testing and evaluation by offering equipment trial rental and leasing programs to assist in such testing and evaluations.

This manual is also suitable for:

3956139560

Table of Contents