Troubleshooting - EUROM POLAR 7000 Instruction Leaflet

Mobile air conditioner/dehumidifier
Table of Contents

Advertisement

Available languages

Available languages

End of season cleaning
If the device is to be stored for a long period, you must take the following measures!
 Remove the condensed water. Run the unit for a few hours on fan function so that the unit is
completely dry inside.
Then switch the air conditioning unit off, remove the plug from the socket and:
 clean the filters and reposition them or replace with new ones;
 unscrew the waste pipe from the device in order to prevent damage;
 pack the air conditioning unit in its original packaging or in a plastic bag and place in a dry
place for storage. Place a heavy object on the unit.
TROUBLE SHOOTING
The unit does not start if I press the ON/OFF button
 Is the plug in the socket?
Is the earth leakage circuit breaker engaged? No power? Fuses in good order?
 Is the set timer time probably not elapsed? Delete the setting.
 Four minutes have not yet elapsed after switching off. Wait for several more minutes.
 Is the water tank full? Empty it.
 The room temperature is lower than the set temperature; amend the set temperature.
The unit doesn't seem to be very effective
 Is the set temperature lower than the ambient temperature?
 Is there direct sunlight? Shut the curtains.
 Are windows or doors open? Shut them.
 Are there too many people in the room? They produce heat!
 Is the space too big?
 Is there an object in the room that is generating (a great deal of) heat? Switch it off or remove
it.
 Is the filter dusty or covered in dirt? Clean it.
 Is the air inlet or outlet (hose) blocked? Make sure there is free air flow.
The unit is making a noise or vibrates
 Is the surface underneath the machine sturdy and even?
The unit switches itself off
 The overheating safeguard may have switched the unit off. See 'Safety'.
An ERROR code appears on the display
 E1: problems with the sensor ambient temperature. Refer to your supplier for repairs. In an
emergency situation, the device can continue to cool or ventilate however, keep an eye on
it as it will not automatically shut down! Automatic function and dehumidifier are not
working.
 E3: automatic defrosting of the humidifier is not working. Refer to your supplier for repairs. In
an emergency situation, you may continue to cool or dehumidify however, you must switch
off the device for 5 minutes once every 30 minutes, in order to allow it to defrost.
 P1: the water tank is full, see: Water ooutlet, page 18.
NEVER ATTEMPT TO REPAIR THE DEVICE YOURSELF!
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Polar 900038.080.438.081.1

Table of Contents