Mollet MOLOSwave MWF2 Series Operating Instructions Manual

Mollet MOLOSwave MWF2 Series Operating Instructions Manual

Microwave level measurement continuous level measuring for bulk goods

Advertisement

Quick Links

M LLET
Füllstandtechnik
Microwave level measurement
continuous level measuring for bulk goods
Index
Safety instructions | Special conditions for ATEX-devices | Use
Data of manufacturer | Receiving department | Application | Function | Design
Technical data | Electrical data | Technical measuring data
Application data | Dimensions | Process connection | Hexagonal nuts
Maximum forces | Mounting position
Installation advices
Installation advices | Preparation of mounting | Mounting
Connection plan | Switching sequence | Electrical connection | Potential compensation
Commissioning | Maintenance | Disposal
Troubleshooting | Returns
MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 Fax +49 6291 9846
Operating instruction
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating instruction
03/20
MWF
Page
02
03
. . . . . . . . . . . . .
04
05
06
07
08
09
. . . . . . .
09
10
MWF-BA-01
01
©
by MOLLET

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MOLOSwave MWF2 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Mollet MOLOSwave MWF2 Series

  • Page 1 ..............MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 Fax +49 6291 9846...
  • Page 2: Safety Instructions

    - Removal, addition or modification of components as far as it is not described in the documentation of the manufacturer. - Violation of applicable standards and laws. MWF-BA-02 03/20 Operating instruction MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 Fax +49 6291 9846 © by MOLLET...
  • Page 3 Counter nut filling good and returned. Connecting sleeve Wire rope probe Rod probe Tensioning weight 002-1000 MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 Fax +49 6291 9846 Operating instruction 03/20 MWF-BA-03 © by MOLLET...
  • Page 4: Technical Data

    <2 mm Inactive area Resolution <1 mm (at reference conditions) Temperature drift <0.2 mm/K Measureable changes of filling level <1 m/s 002-1001 MWF-BA-04 03/20 Operating instruction MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 Fax +49 6291 9846 © by MOLLET...
  • Page 5 G1½ 14. Hexagonal nuts 001-0150 Art.-No. Thread For thread code SM1E 1.4301 SM2E G1¼ 1.4301 Ø 6 SM3E G1½ 1.4301 Ø30 002-1004 MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 Fax +49 6291 9846 Operating instruction 03/20 MWF-BA-05 © by MOLLET...
  • Page 6: Mounting Position

    (~ ¾ to ~ ¼ of silo diameter). 002-1006 MWF-BA-06 03/20 Operating instruction MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 Fax +49 6291 9846 © by MOLLET...
  • Page 7: Installation Advices

    002-1009 provided on site either reliably grounded or reliably isolated. Reliably grounded fixing Reliably isolated fixing MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 Fax +49 6291 9846 Operating instruction 03/20 MWF-BA-07 © by MOLLET...
  • Page 8 - Screw the MWF into a screw socket or a flange with internal thread. - Do not screw in MWF by its housing. Use the hexagon at the process connection. MWF-BA-08 03/20 Operating instruction MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 Fax +49 6291 9846 © by MOLLET...
  • Page 9: Maintenance

    - Level measurement device MWF can be recycled. - Disposal of the MWF is subject to the environmental legislation of the respective country in effect for the operator's premises. 001-1011 MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 Fax +49 6291 9846 Operating instruction 03/20 MWF-BA-09 ©...
  • Page 10: Troubleshooting

    Parameterisation not correct Adapt parameterisation after consultation of MOLLET 27.1 If the malfunction persists, the MWF has to be returned to MOLLET for review of the device function. 28. Returns 28.1 Remove all adherent material residues of filling material from the MWF.
  • Page 11 M LLET EUKE-MWF Index Füllstandtechnik Seite/Page von/of EU-Konformitätserklärung EU-Declaration of Conformity MOLLET Füllstandtechnik GmbH Wir/We Industriepark RIO 103 D-74706 Osterburken Tel. 06291 64400 Fax 06291 9846 erklären in alleiniger Verantwortung, dass das Produkt: declares under our sole responsibility, that the product: Mikrowellen-Füllstandanzeiger / Microwave level indicator...

This manual is also suitable for:

Moloswave mwf27Moloswave mwf21

Table of Contents