System Piping; Aligning The Dosing Head; Hydraulic Connections - Neptune NXP-M Operating Instructions Manual

Neptune stepper motor-driven diaphragm pump
Table of Contents

Advertisement

Stepper motor-driven diaphragm dosing pump NXP-M and NXP-P

8.2 System piping

The system piping must not exert any force on the connections and
n
valves of the dosing pump.
This means that steel piping should be connected to the dosing pump
n
by means of flexible pipe sections.
The nominal diameters of the pipework and the installed fittings
n
should be rated the same as or greater than the nominal diameters of
the dosing pump's suction and discharge valves.
The suction line should be kept as short as possible.
n
You should avoid intertwined hoses.
n
Avoid loops, since air bubbles can collect.
n

8.3 Aligning the dosing head

Fig. 12: Aligning the dosing head
When connecting the dosing lines to the dosing pump, you must observe
the direction of through-flow (see arrow 2). The dosing head must be
aligned vertically. The alignment can be changed in 90° intervals.
The suction valve (3) must always point downwards. Accordingly, arrow
(2) and pressure valve (1) always point upwards. This is irrespective of the
positioning of the dosing head to the drive.
Subject to technical changes.

8.4 Hydraulic connections

8.4.1 Connecting hose clips
Choose the hose connection according to the condition of the hose
(material, inner diameter, wall thickness) in order to ensure maximum
pressure resistance.
8.4.1.1 Size 4/6
a
b
Fig. 13: Hose clips 4/6 and 6/9 (internal and external diameters in mm)
c
Perform the following working steps:
1. Cut the hose (1) to the appropriate length neatly and at an exact right
angle.
2. Place a gasket that is suitable for the dosing medium between the
connection (5) and the valve.
3. Screw the connecting piece to the dosing pump's valve using the
union nut (2).
4. Thread the union nut (3) and the clamping ring (4) onto the hose.
5. Plug the hose all the way in to the grommet of connection piece.
6. Push the clamping ring onto the grommet of connection piece and
screw it to the union nut.
7. Carry out the same procedure with the connection to the dosing
pump's other valve.
ü
Hose clip connected.
6/9
4/6
a
b
c
d
e
Operating instructions
a
b
c
d
e
Hydraulic installations
19
Hydraulic connections

Advertisement