2. Restore
# Example PATH_FOR_BACKUP=~/backup
export PATH_FOR_BACKUP=~/backup
# Example DATABASE_VOLUME=mcmanager_sqldata
export DATABASE_VOLUME=mcmanager_sqldata
docker stop mcm_database
docker volume create $DATABASE_VOLUME
docker run --rm -v $DATABASE_VOLUME:/recover -v
$PATH_FOR_BACKUP:/backup ubuntu bash -c "cd /recover && tar xvf
/backup/mcm_database.tar"
docker start mcm_database

MobileConnect Manager remove installation

You can remove your MobileConnect Manager in the following way:
cd YOUR_MANAGER_INSTALLATION_DIR
docker-compose down

MobileConnect Station update

The software upgrade and downgrade of a MobileConnect Station can be performed using the MobileConnect
Manager.
Connect your MobileConnect Station to your MobileConnect network
Open the MobileConnect Manager and go to Stations
Select your device
Click "Recheck firmware versions" to check for the latest firmware version
Click "Start update"
Select a version and click "Update now"
For upgrading a MCS v1 from software version 5.1.0 to higher, see section
ConnectStation.