Chengdu Ebyte Electronic Technology Co., Ltd.
affect the performance. It is recommended to keep them away from the module according to the strength of the
interference. If necessary, appropriate isolation and shielding can be done;
Assume that there are traces with large electromagnetic interference (high-frequency digital, high-frequency analog,
power traces) around the module that will greatly affect the performance of the module. It is recommended to stay
away from the module according to the strength of the interference.If necessary, appropriate isolation and shielding
can be done.
If the communication line uses a 5V level, a 1k-5.1k resistor must be connected in series (not recommended, there is
still a risk of damage);
Try to stay away from some physical layers such as TTL protocol at 2.4GHz , for example: USB3.0;
The mounting structure of antenna has a great influence on the performance of the module. It is necessary to ensure
that the antenna is exposed, preferably vertically upward. When the module is mounted inside the case, use a good
antenna extension cable to extend the antenna to the outside;
The antenna must not be installed inside the metal case, which will cause the transmission distance to be greatly
weakened.

4.2 Software editing

SX1278/SX1276+PA+LNA,same drive way as SX1278/SX1276,user can refer to SX1278/SX1276 datasheet.
DIO0、DIO1、DIO2、DIO3、DIO4、DIO5 are configurable I/O ports for various application,see more in SX1278
datasheet. It can be floated when not used.
RST、 TXEN、 RXEN must be connected,among which RST control chip reset, TXEN, RXEN are for controlling RF
switch.
Make it ground well with large space for grounding and small power ripple. Filter capacitor is necessary and make
sure it is close to pin VCC and GND.
SPI communication rate should not be set too high, usually around 1Mbps.
In transmitting,set TXEN as high communication level,RXEN pin is low level; In receiving, set RXEN as high
communication level,TXEN is low level; Before powering off, set TXEN、RXEN as low level.
Re-initialize register configuration when the chip is idle for higher stability.