determine loading limitations. It is important that the loading
limitations are not exceeded.
Connect the unit to an earthed power supply to ensure
compliance with safety standards.
It is essential that the socket outlet is installed near to the unit
and is easily accessible. You can only disconnect the unit by
removing the supply plug from the outlet.
If installing the Advanced RPS Chassis in a stack with
SuperStack units, place the Advanced RPS Chassis at the
bottom of the stack.
This unit operates under SELV conditions (Safety Extra Low
Voltage) according to IEC 60950, the conditions of which are
maintained only if the equipment to which it is connected also
operates under SELV.
The appliance coupler (the connector to the device itself and not
the wall plug) must have a configuration for mating with an
EN60320/IEC320 appliance inlet.
Use only the special cables designed and supplied for this
product.
Power Cord Set:
This must be approved for the country where it is used:
U.S.A. and
Canada
United
Kingdom
only
I
AFETY
NFORMATION
The cord set must be UL-approved and CSA certified.
The minimum specification for the flexible cord is:
No. 18 AWG
Type SV or SJ
3-conductor
The cord set must have a rated current capacity of at least
10A.
The attachment plug must be an earth-grounding type with
a NEMA 5-15P (15A, 125V) or NEMA 6-15P (15A, 250V)
configuration.
The supply plug must comply with BS1363 (3-pin 13 amp)
and be fitted with a 5A fuse which complies with BS1362.
The mains cord must be <HAR> or <BASEC> marked and
be of type H03VVF3GO.75 (minimum).