Carrier 58MVP 170 Series Troubleshooting Manual page 28

Variable speed, two-stage electronic condensing four-way multipoise gas furnace
Table of Contents

Advertisement

STEP
Check connections and retry. If current is near typical value
(4.0 to 6.0 microamps) and main burners will not stay on
longer than a few seconds, check the following:
- Air leakage around igniter bracket.
- Inadequate flame carryover on rough ignition.
31
- Low manifold pressure. Reference installation instructions
- Slow opening gas valve. Gas should flow at full pressure
within 4 seconds after the gas valve is energized.
If the above items are OK replace the variable speed fur-
Clean flame sensor with fine sandpaper and make sure it is
32
properly positioned then recheck current. Current is typically
33
34
35
Will main burners ignite and stay on?
36
- Make sure perforated disks are in combustion-air
- Pressure tubing going to gas valve air pressure fitting for
- Remove gas valve air pressure fitting and check gas valve
37
- Ensure vent and combustion-air pipes are not reversed.
- Add restriction to combustion-air pipe or lengthen a few
38
While the unit is operating in low heat jumper R and W2.
39
Do you have burner pulsation's in high heat?
Turn off the power and disconnect the jumper across the R
40
Turn power on and jumper R, W/W1, and W2 thermostat
41
42
43
Do the main burners stay on longer than a few seconds?
44
45
46
Furnace will operate at low-heat but will not ignite on low-
- Low manifold pressure. Reference installation instructions
47
for proper low-heat manifold pressure.
- Slow opening gas valve. Gas should flow at full pressure
within 4 seconds after the gas valve is energized.
- Air leakage around igniter bracket.
Furnace will not operate or ignite on low-heat. Check the
48
Reference installation instructions for proper low-heat mani-
fold pressure. Turn low-heat regulator adjustment clockwise
1/4 turn. Repeat until furnace will operate in low-heat. Then
set to the proper manifold pressure. Re-orifice if necessary.
ACTION
- Low inlet gas pressure.
for proper manifold pressure.
nace control.
4.0 to 6.0 microamps.
Is current near typical value?
Replace electrode.
Do you have burner pulsation's?
Check the following:
vent inlet.
kinks.
for blockage.
- Burner orifice size and alignment.
- Inadequate flame carryover.
feet if possible.
and W/W1 thermostat terminals.
terminals.
Do the main burners ignite?
Do you have burner pulsation's?
Disconnect jumper from R and W2.
Do the main burners remain ON?
heat. Check the following:
- Inadequate flame carryover.
- Flame sensor location.
following:
- Flame sensor location.
- Very low manifold pressure.
YES
35
37
37
43
44
37
47
28
NO
GO TO
8
33
34
8
183
38
8
39
8
41
42
25
27
45
46
48
8
8