Status Code 11-No Previous Code; Status Code 12-Blower On After Power Up - Carrier 58MVP 170 Series Troubleshooting Manual

Variable speed, two-stage electronic condensing four-way multipoise gas furnace
Table of Contents

Advertisement

STEP
13
Is outdoor condensing unit operating during heating cycle?
Check temperature rise and external static pressure with
blower access panel in place. Temperature rise should be
mid range or higher than midpoint of range stated on fur-
14
nace rating plate. External static pressure must not exceed
.7 in.w.c. If return temperature is below 60 degrees F, con-
densation may form on heat exchangers. If left uncorrected,
15
Check return air ducts in unheated spaces for leaks.
16
Status Code 11
NO PREVIOUS CODE – Stored status codes are erased after 72 hours or can be cleared by jumpering R, W/W1, and Y/Y2 thermostat leads
while setup switch SW1-1 is ON. Run system through a heating or cooling cycle to check system.
This usually indicates one of the following:
• The status history has been cleared and setup switch SW1-1 is in the ON position.
• Component test was successfully completed and setup switch SW1-6 is in the ON position.
STEP
Remove the blower access panel, depress the door switch.
1
2
3
Go to the page number indicated in Index for the CLEANUP
4
5
6
Jiggle setup switches SW1-1 and SW1-6 back and forth. If
7
status code 11 continues to flash replace the variable
Status Code 12
BLOWER ON AFTER POWER UP - Blower will run for 90 seconds when furnace power is interrupted and later restored during a call for
heat (R-W/W1 closed) or if the call for heat is interrupted (R-W/W1 opens) during the blower on-delay period. If this status code repeats every
couple of minutes it is probably caused by a direct short in the pressure switch circuits, gas valve GV, wiring to gas valve GV, or humidifier
coil.
STEP
Remove the blower access panel and disconnect the W/W1
1
thermostat lead from the variable speed furnace control.
Depress the door switch. Use piece of tape to hold it
2
Set thermostat to call for heat and set the thermostat fan
control to AUTO position if equipped. Then reconnect the
3
W/W1 thermostat lead to the variable speed furnace con-
Does the furnace keep repeating the following cycle?
Induced draft motor IDM runs, induced draft motor IDM
4
stops, blower motor BLWM runs for 90 seconds while AM-
Do you have less than 17-vac across R and C
5
Do you have less than 90-vac across L1 and NEUTRAL-L2
6
Make sure wire gage between main fuse box and furnace
7
complies with wire size specification in Installation, Start-Up,
8
Go to the page number indicated in Index for the CLEANUP
9
10
Do you have less than 19-vac across R and C
11
12
ACTION
failure will result.
Fix problem.
ACTION
Use piece of tape to hold it closed.
Is setup switch SW1-1 in the ON position.
Put setup switch SW1-1 in the OFF position.
AND STARTUP INSTRUCTIONS.
Is setup switch SW1-6 in the ON position.
Put setup switch SW1-6 in the OFF position.
speed furnace control
ACTION
closed.
trol.
BER LED status light flashes status code 12.
the variable speed furnace control?
on the variable speed furnace control?
and Operating Instructions.
Fix problem.
AND STARTUP INSTRUCTIONS.
Disconnect the R thermostat lead.
the variable speed furnace control?
Replace transformer.
YES
16
YES
3
6
YES
5
-24V on
OM
6
7
-24V on
OM
12
14
NO
GO TO
14
15
9
9
NO
GO TO
2
5
4
INDEX
7
4
4
NO
GO TO
2
3
4
20
14
10
8
9
INDEX
11
13
9