STAR Radiant Heater for Fixed Overhead Intallations
FIRE HAZARD. Do not use as a residential or house-
hold heater. Keep combustible material away from
heater. Do not operate heater where flammable va-
pors, gases or liquids are present.
To avoid personal injury read "IMPORTANT INSTRUC-
TIONS" on this page before installation or operation
of heater.

Installation

The Chromalox STAR radiant heater is shipped fully assem-
bled. The heater can be hung from the ceiling with 4 chains or
rigid angle brackets attached to the heater brackets located
on the back of the heater, for 2 and 4.5 kW heaters, chains
can be attached to the four holes in the corners of the back
reflector. (Chromalox offers hanging chain kits for these heat-
ers that will allow for installations 2 to 6 feet from the ceiling.)
Minimum spacings:
Ceiling to top of heater is 2 feet.
Wall to sides of heater is 3 feet.
Floor to bottom of heater is 10 feet.
Installer should consult state and local codes and
meet any applicable requirements regarding the in-
stallation.
FIRE HAZARD. Radiant heaters are capable of devel-
oping high temperatures, care should be taken to:
A. Mount heater with the proper clearance between
heater and walls, ceiling and floor.
B. Mount heater in horizontal position only. Do not
mount vertically or tilted in any direction.
C. Do not mount heater over combustible surfaces.
D. Do not stack or store combustible materials di-
rectly below the heater or in the space a dis-
tance of 5 feet from any projected edge of the
heater.
E. Do not operate the heater without Ground Fault
Equipment Protection.
Failure to follow these instructions can result in per-
sonal injury and fire.
IMPORTANT: SAVE THESE INSTRUCTIONS
ELECTRIC SHOCK AND FIRE HAZARD. This radiant
heater is a component of the complete heating sys-
tem. The heating system designer must consider
the risks associated with its operation and specify
adequate controls and safety devices. Where the
consequences of failure could result in personal in-
jury, property damage or fire, back-up controls are
essential.
5 Feet
Min.
Floor - Non combustible surface
3
5 Feet
Min.
Shaded area
must be
kept clear of
combustible
materials