Download Print this page

Chromalox STAR-02A-11-F Installation, Operation And Renewal Parts Identification

Type star radiant heater for fixed overhead installations

Advertisement

Quick Links

http://www.chromalox.com
11-9/16"
9-7/8"
11-1/2"
Specifications – Table 1
Model
Figure
STAR-02A-11-F
STAR-02A-81-F
STAR-02A-21-F
STAR-02A-71-F
STAR-02A-41-F
STAR-02A-61-F*
STAR-05A-81-F
STAR-05A-21-F
STAR-05A-71-F
STAR-05A-41-F
STAR-05A-61-F*
STAR-06A-83-F
STAR-06A-23-F
STAR-06A-71-F
STAR-06A-43-F
STAR-06A-63-F*
STAR-14A-83-F
STAR-14A-23-F
STAR-14A-71-F
STAR-14A-43-F
STAR-14A-63-F*
* Not UL or CSA
NA - Not Available
NR - Not Recommended
© 2003 Chromalox, Inc.
Type STAR Radiant Heater
For Fixed Overhead Installations
2.0 kW
33-1/4"
6.0 kW
23-5/8"
Amperage
Volts
KW
1 Phase
120
1.5
12.5
208
2
9.6
1
240
2
8.3
277
2
7.2
480
2
4.2
600
2
3.3
208
4.5
21.6
240
4.5
18.8
1
277
4.5
15.9
480
4.5
9.4
600
4.5
7.5
208
6
28.8
240
6
25.0
2
277
6
21.7
480
6
12.5
600
6
10.0
208
13.5
NR
240
13.5
NR
2
277
13.2
47.7
480
13.5
28.1
600
13.5
22.5
11-9/16"
9-7/8"
23-5/8"
Figure 1
32-1/2"
Figure 2
BTU
3 Phase
A Length
NA
5118
NA
6824
NA
6824
33-1/4
NA
6824
NA
6824
NA
6824
NA
15354
NA
15354
NA
15354
55-3/4
NA
15354
NA
15354
16.7
20472
14.4
20472
20472
32-1/2
7.2
20472
5.8
20472
37.5
46062
32.5
46062
45038
55-5/8
16.2
46062
13.0
46062
(Supersedes PG434-1)
JULY, 2003
4.5 kW
55-3/4"
13.5 kW
11-1/2"
23-5/8"
55-5/8"
Dimensions (In.)
B Width
D Depth
1 Phase
15-1/2
11-9/16
15-1/2
11-9/16
23-5/8
11-1/2
23-5/8
11-3/4
PG434-2
15-1/2"
Wire Ga. (Min.)
3 Phase
14
NA
14
NA
14
NA
14
NA
14
NA
14
NA
12
NA
12
NA
14
NA
14
NA
14
NA
10
12
10
12
10
12
12
12
12
NR
10
NR
10
8
12
12
12
12

Advertisement

loading

Summary of Contents for Chromalox STAR-02A-11-F

  • Page 1 46062 STAR-14A-23-F 13.5 32.5 46062 STAR-14A-71-F 13.2 47.7 — 45038 55-5/8 23-5/8 11-3/4 STAR-14A-43-F 13.5 28.1 16.2 46062 STAR-14A-63-F* 13.5 22.5 13.0 46062 * Not UL or CSA NA - Not Available NR - Not Recommended © 2003 Chromalox, Inc.
  • Page 2: Installation

    2 and 4.5 kW heaters, chains can be attached to the four holes in the corners of the back reflector. (Chromalox offers hanging chain kits for these heaters that will allow for instal- lations 2 to 6 feet from the ceiling.) Minimum spacings:...
  • Page 3: Optional Accessories

    8. Connect entrance wiring to pigtail leads “L1” and “L2”. Connect ground to screw provided. 9. Inspect to make sure wiring is per “Single Phase Wiring” above. OPTIONAL ACCESSORIES Chromalox STAR series radiant heaters can be field modified Hanger Kit by adding optional kits. Refer to Chart A to select the proper kit.
  • Page 4: Maintenance

    8. Remove failed element and replace with a new element. before servicing or replacing heating elements. Replace only with genuine Chromalox "Arctic End" elements. Use of other elements will cause excess temperatures inside The reflectors should be kept clean to obtain the maximum terminal box.
  • Page 5 RENEWAL PARTS IDENTIFICATION Element Housing Terminal Box Model Element*** Reflector Safety Screen Gasket STAR-02A-11-F PCN 106059 PCN 111878 132-304879-004 STAR-02A-81-F PCN 106067 PCN 111878 132-304879-004 STAR-02A-21-F PCN 106075 234-891755-004 PCN 111878 132-304879-004 STAR-02A-71-F PCN 106083 PCN 111878 132-304879-004 STAR-02A-41-F...
  • Page 6 RELATING HERETO, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE AND extent and in the manner that the same are warranted to Chromalox by Chromalox’s vendors, and then only STRICT LIABILITY) OR OTHER THEORIES, MUST BE COMMENCED WITHIN ONE (1) YEAR AFTER THE to the extent that Chromalox is reasonably able to enforce such warranty, it being understood Chromalox DATE OF SHIPMENT OR IT SHALL BE BARRED.

This manual is also suitable for:

Star-02a-81-fStar-02a-21-fStar-02a-71-fStar-02a-41-fStar-02a-61-fStar-05a-81-f ... Show all