Download Print this page
Chromalox STAR PG434-3 Installation & Operation Manual

Chromalox STAR PG434-3 Installation & Operation Manual

Type star radiant heater for fixed overhead installations

Advertisement

Quick Links

11-9/16"
15-1/2"
11-1/2"
Specifications – Table 1
Model
Figure
STAR-02A-11-F
STAR-02A-81-F
STAR-02A-21-F
STAR-02A-71-F
STAR-02A-41-F
STAR-02A-61-F*
STAR-05A-81-F
STAR-05A-21-F
STAR-05A-71-F
STAR-05A-41-F
STAR-05A-61-F*
STAR-06A-83-F
STAR-06A-23-F
STAR-06A-71-F
STAR-06A-43-F
STAR-06A-63-F*
STAR-14A-83-F
STAR-14A-23-F
STAR-14A-71-F
STAR-14A-43-F
STAR-14A-63-F*
* Not UL or CSA
NA - Not Available
NR - Not Recommended
© 2010 Chromalox, Inc.
Type STAR Radiant Heater
For Fixed Overhead Installations
2.0 kW
33-1/4"
6.0 kW
23-5/8"
Amperage
Volts
KW
1 Phase
120
1.5
12.5
208
2
9.6
1
240
2
8.3
277
2
7.2
480
2
4.2
600
2
3.3
208
4.5
21.6
240
4.5
18.8
1
277
4.5
15.9
480
4.5
9.4
600
4.5
7.5
208
6
28.8
240
6
25.0
2
277
6
21.7
480
6
12.5
600
6
10.0
208
13.5
NR
240
13.5
NR
2
277
13.2
47.7
480
13.5
28.1
600
13.5
22.5
11-9/16"
15-1/2"
Figure 1
32-1/2"
Figure 2
BTU
3 Phase
A Length
NA
5118
NA
6824
NA
6824
33-1/4
NA
6824
NA
6824
NA
6824
NA
15354
NA
15354
NA
15354
55-3/4
NA
15354
NA
15354
16.7
20472
14.4
20472
20472
32-1/2
7.2
20472
5.8
20472
37.5
46062
32.5
46062
45038
55-5/8
16.2
46062
13.0
46062
(Supersedes PG434-3)
SEPTEMBER, 2009
4.5 kW
B B
55-3/4"
13.5 kW
11-1/2"
23-5/8"
55-5/8"
Dimensions (In.)
B Width
D Depth
1 Phase
15-1/2
11-9/16
15-1/2
11-9/16
23-5/8
11-1/2
23-5/8
11-3/4
PG434-4
Wire Ga. (Min.)
3 Phase
14
NA
14
NA
14
NA
14
NA
14
NA
14
NA
12
NA
12
NA
14
NA
14
NA
14
NA
10
12
10
12
10
12
12
12
12
NR
10
NR
10
8
12
12
12
12

Advertisement

loading

Summary of Contents for Chromalox STAR PG434-3

  • Page 1 STAR-06A-43-F STAR-06A-63-F* STAR-14A-83-F STAR-14A-23-F STAR-14A-71-F STAR-14A-43-F STAR-14A-63-F* * Not UL or CSA NA - Not Available NR - Not Recommended © 2010 Chromalox, Inc. Type STAR Radiant Heater 2.0 kW 33-1/4" Figure 1 6.0 kW 23-5/8" 32-1/2" Figure 2 Amperage...
  • Page 2: Installation

    2 and 4.5 kW heaters, chains can be attached to the four holes in the corners of the back reflector. (Chromalox offers hanging chain kits for these heaters that will allow for instal- lations 2 to 6 feet from the ceiling.) Minimum spacings:...
  • Page 3: Optional Accessories

    8. Connect entrance wiring to pigtail leads “L1” and “L2”. Connect ground to screw provided. 9. Inspect to make sure wiring is per “Single Phase Wiring” above. Chromalox STAR series radiant heaters can be field modified by adding optional kits. Refer to Chart A to select the proper kit.
  • Page 4: Maintenance

    7. Remove bulkhead fitting nuts and washers. 8. Remove failed element and replace with a new element. Replace only with genuine Chromalox "Arctic End" elements. Use of other elements will cause excess temperatures inside terminal box. 9. Place gasket on the bulkhead fitting and insert terminals and fit- tings into the element holes in the terminal box.
  • Page 5 Model Element*** STAR-02A-11-F PCN 106059 STAR-02A-81-F PCN 106067 STAR-02A-21-F PCN 106075 STAR-02A-71-F PCN 106083 STAR-02A-41-F PCN 106091 STAR-02A-61-F PCN 106104 STAR-05A-81-F PCN 106403 STAR-05A-21-F PCN 106411 STAR-05A-71-F PCN 106796 STAR-05A-41-F PCN 106964 STAR-05A-61-F PCN 106972 STAR-06A-83-F PCN 106067 STAR-06A-23-F PCN 106075 STAR-06A-71-F PCN 106083 STAR-06A-43-F...
  • Page 6 Limited Warranty: Please refer to the Chromalox limited warranty applicable to this product at http://www.chromalox.com/customer-service/policies/termsofsale.aspx. 2150 N. RULON WHITE BLVD., OGDEN, UT 84404 Phone: 1-800-368-2493 www.chromalox.com...

This manual is also suitable for:

Star pg434-4Star-02a-11-fStar-02a-81-fStar-02a-21-fStar-02a-71-fStar-02a-41-f ... Show all