Cablite Emergency Board Leds; Installation - ECI CabLite VR Series Installation Manual

Led lighting system
Table of Contents

Advertisement

Cablite® VR LED Lighting System Installation Manual Rev 2.1
Pin 2 (IN-) is -12 or -24VDC input (BLACK Wire)
Pin 3 (OUT+) is + output for general power (AC present) Downlight String (RED Wire)
Pin 4 (OUT-) is – output for general power downlight string (BLACK Wire)
Pin 5 & 6 is for external potentiometer (customer provided) for brightness adjustment
Pin 7 (EM+) is + output for EMERGENCY downlight string (2 downlights) (RED wire)
Pin 8 (EM-) is – output for EMERGENCY downlight string (2 downlights) (Black wire)
Pin 9 & 10 (STBY) – is for external key switch that turns all downlights off when pin 9 & 10 are
closed. When closed EMERGENCY downlights will light only if AC power is lost.
Pin 11 (BAT+) + side connection to battery
Pin 12 (BAT-) – side connection to battery
Pin 13 is FAULT relay common
Pin 14 is Normally Closed contact of fault relay: Contacts open (between Common pin 13) when
there is a Battery Fault
Pin 15 is the Normally open contact of the fault relay: Contacts close (between Common pin 13)
when there is a battery fault.

6.4.2 CabLite Emergency Board LEDs

CHARGE – the charge LED blinks when the battery is charging and remains solid when battery
is fully charged.
FAULT – The fault LED lights when there is a problem with the battery. Wrong voltage or not
charging.

7 Installation

Be sure all power is turned off before starting installation.
Figure 3 - CabLite VR Emergency Board
Electronic Controls, Inc.
7073 North Atlantic Ave. Cape Canaveral, FL 32920
800-633-9788
www.eciamerica.com
P a g e
| 9