Trouble Display - Haier AU122AEERA Installation Instructions Manual

Dc inverter, outdoor unit
Hide thumbs Also See for AU122AEERA:
Table of Contents

Advertisement

Installation Procedure
(1) Before starting test run (for all Heat pump models)
(2) Test run

10. Trouble display

Trouble description
Spdu module failure
Abnormal of DC moter
Communication error between indoor and outdoor
unit
Compressor discharging temprerture protection
Spdu module over current protection
Abnormal of outdoor
ambient
Abnormal of piping sensor or suction sensor
High pressure protection
Abnormal of compressor discharge sensor
The power supply is not the 50Hz
Eeprom failure
Compressor JAM
Compressor vibration abnormal
Compressor start-up abnormal
Rotor of inner compressor is malposition
Position-inspect circuit failure
Compressor failure
Compressor suction sensor over high
Communication error between main board and
spdu module
Spdu module temperture protection
Low pressure protection
Display of LED borad
LED 5-4-3-2-1
00001
00010
00011
00100
00101
sensor
00110
00111
01000
01001
01010
01110
01111
10000
10001
10010
10011
10100
10101
10110
10111
11000
Electric wiring
Analyze and diagnose
Spdu module failure
Jam of DC motor or motor failure
Communication fail over 4min
Compressor discharging tempreature
over 120 centigrade
Current of spdu module over 21A last
4sec
Outdoor
ambient
sensor short-circuit or
open-circuit last 3sec
Piping sensor or suction sensor short-
circuit or open-circuit last 3sec
System high pressure over 4.5Mpa
Compressor discharge sensor short-
circuit or open-circuit
The power supply is not the 50Hz
Outdoor main board eeprom fail
Inner compressor is
abnormal
Compressor vibration abnormal when
start-up
Compressor start-up abnormal
Rotor of inner compressor is malposition
when start-up
Position-inspect circuit failure of spdu
module
Compressor failure
In operation the suction temperature
over 40 centigrade
Communication error between main
board and spdu module
Spdu module temperture is too high
System low pressure
under
0.05Mpa
JAMED

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents