Kärcher LEUCO HAWK NMT-EBCW Series Instruction Manual For Operation And Maintenance page 6

High pressure piston pumps
Table of Contents

Advertisement

XLTI-ESA
NMT-EBCH
XLTI-EBCH
Hawk pumps must not be used with other materials/fluids and other motor coupling devices from those
specified hereto.
If you have doubts, contact the Manufacturer.
The main parameters for the selection of a Hawk pump are the flow rate, the pressure, the rotation speed and the absorbed power.
The flow rate, expressed in litres per minute, is directly proportional to the rotation speed.
The rotation speed is expressed in revolutions per minute.
The pressure is expressed in bar and it is the max. pressure admissible from the pump.
The absorbed power is expressed in kW and it identifies the absorption required to achieve the max. flow rate and pressure
performances specified.
If the pump is coupled with an electric motor, the power of the selected motor must be greater than that specified in the catalogue.
If the pump is coupled with a combustion motor, the power of the selected motor shall be at least 30% greater than that specified in
the catalogue.
The absorbed power of the pump, expressed in kW, is calculated with the following formula:
Before selecting and/or using a LEUCO product, the buyer should carefully analyse all the aspects
concerning its application and should examine in depth the information provided in the technical and
commercial brochures issued by LEUCO S.p.A.
The products and this document may be subjected to modifications by LEUCO at any time and without
prior notice.
This Manual is the exclusive property of the Manufacturer. Reproduction, in any form whatsoever, even partially, is prohibited.
High pressure piston pumps – Series NMT-EBCW, NMT-EBCH, XLTI-EBCH, XLTI-ESA
WATER
WATER WITH ALKALINE OR ACID DETERGENTS IN 0 TO 2% CONCENTRATION
NITRIC ACID IN WATER SOLUTION WITH A MAX. CONCENTRATION OF 10%
ACETIC ACID IN WATER SOLUTION WITH A MAX. CONCENTRATION OF 10%
FORMIC ACID IN WATER SOLUTION WITH A MAX. CONCENTRATION OF 10%
PHOSPHORIC ACID IN WATER SOLUTION WITH A MAX. CONCENTRATION OF 10%
CITRIC ACID IN WATER SOLUTION WITH A MAX. CONCENTRATION OF 0.5%
SULFURIC ACID IN WATER SOLUTION WITH A MAX. CONCENTRATION OF 0.5%
HYDROCHLORIC ACID IN WATER SOLUTION WITH A MAX. CONCENTRATION OF 0.5%
CAUSTIC SODA IN WATER SOLUTION WITH A MAX. CONCENTRATION OF 10% (NO HYPOCHLORITE)
WATER
DEMINERALISED/DESALTED WATER
WATER WITH ALKALINE OR ACID DETERGENTS IN 0 TO 2% CONCENTRATION
HYDROCARBONS SUCH AS GASOLINE OR HEAVY OIL
AROMATIC SOLVENTS SUCH AS BENZENE AND TOLUENE
KETONS SUCH AS ACETON OR METHYL ETHYL KETONE
ESTERS SUCH AS BUTYL ACETATE OR METYL ACETATE
GLYCOLS SUCH AS BUTYL GLYCOLE
SOLVENT MISTURES SUCH AS 85% BUTYL ACETATE AND 15% N-BUTYLIC ALCOHOL
Power = Flow rate (l/min) x Pressure (bar) / 520.