  • Page 1 GRUNDFOS INSTRUCTIONS Unilift CC 5, CC 7, CC 9 Installation and operating instructions...
  • Page 2: Table Of Contents

    Read this document before installing the These installation and operating instructions product. Installation and operation must describe Grundfos Unilift CC 5, CC 7 and CC 9. comply with local regulations and Sections 1-5 give the information necessary to be accepted codes of good practice.
  • Page 3: Limited Warranty

    Grundfos' warranty. CAUTION Grundfos will not be liable for damage or wear to products caused by abnormal operating conditions, Indicates a hazardous situation accident, abuse, misuse, unauthorized alteration or...
  • Page 4: Notes

    4. Installing the product 2.2 Notes The symbols and notes below may appear in DANGER Grundfos installation, operating, safety and service instructions. Electric shock Death or serious personal injury - The installation, electrical Observe these instructions for connection, and maintenance of explosion-proof products.
  • Page 5: Lifting The Product

    4.1 Lifting the product DANGER Lift the pump by the lifting handle. Never lift the Electric shock pump by the power cable. Tie a rope to the lifting Death or serious personal injury handle instead. - Do not remove the power cable and strain relief.
  • Page 6 4.2.2 Location Minimum pit dimensions for a pump with a float switch: Unilift CC 5, CC 7 and CC 9 pumps are suitable for both stationary and portable use. Height (H) Height (H) Minimum free cable length Pump (top outlet...
  • Page 7 4.2.5 Positioning the product 4.2.7 Using the side outlet port When the pipe or hose has been connected, place If you want to use the side outlet port, proceed as the pump in its operating position. follows: Position the pump so that the inlet strainer will not be 1.
  • Page 8: Electrical Connection

    4.2.8 Adjusting the cable length for a float switch 4.2.9 Lever arm start and stop levels To make sure that the float switch can start and stop the pump, the free cable length must be: • at least 3.9 inches (100 mm) •...
  • Page 9: Starting Up The Product

    5. Starting up the product DANGER Electric shock DANGER Death or serious personal injury Electric shock - If the pump is used for cleaning or Death or serious personal injury other maintenance of swimming - Do not use the pump in swimming pools, garden ponds or similar pools, garden ponds or similar places, make sure that the power...
  • Page 10: Venting The Product

    5.2 Venting the product 5.5 Pumping to a low water level The pump is self-venting. A vent valve is built into The pump can pump down to 0.12 inch (3 mm) when the lifting handle. The valve allows air to escape from the inlet strainer is removed.
  • Page 11: Product Introduction

    6. Product introduction 6.1 Product description Grundfos Unilift CC 5, CC 7 and CC 9 pumps are single-stage submersible pumps designed for pumping rainwater and grey wastewater without fibers. The pumps are self-venting and incorporate a vent valve. The pumps are designed for manual or automatic operation.
  • Page 12: Applications

    Unilift CC 5 is for indoor use only. Unilift CC 7 and etc. when there are persons in the CC 9 are suitable for both indoor and outdoor use.
  • Page 13: Identification

    7. Servicing the product 6.3 Identification 6.3.1 Nameplate 7.1 Maintaining the product Under normal operating conditions, the pump is maintenance-free. If the pump has been used for liquids other than clean water, it must be flushed through with clean water immediately after use. See section 7.2 Cleaning the pump.
  • Page 14: Cleaning The Pump

    The part numbers and the components pump. included in the service kits are found in Grundfos Product Center at www.grundfos.us. Alternatively, 7.2.1 Cleaning the inlet strainer contact your local Grundfos dealer or service center.
  • Page 15: Fault Finding The Product

    There is a short circuit in the Replace the defective part. cable or motor. The motor The temperature of the pumped Contact your Grundfos protection or liquid is too high. representative. thermal relay The impeller is blocked or partly Clean the pump.
  • Page 16: Technical Data

    9. Technical data 9.1.4 Inlet level and installation depth 9.1 Operating conditions Min. inlet level Min. inlet level Pump with inlet without inlet 9.1.1 Flow rate type strainer strainer [in. (mm)] [in. (mm)] Max. head Max. flow rate Pump type CC 5 0.79 (20) 0.12 (3)
  • Page 17: Mechanical Data

    This product or parts of it must be disposed of in an environmentally sound way: 1. Use the public or private waste collection service. 2. If this is not possible, contact the nearest Grundfos company or service workshop. See also end-of-life information at www.grundfos.com/product-recycling.