7. Problem solving

Failure
Possible cause
There is no suction • Wrong direction of rotation
• Valve in suction line or pressure
• Synthetic plugs are still in inlet or
• Insufficient de-aeration
• For self-priming pumps: pressure
Pump flow is too
• There is no suction
low
• Wrong direction of rotation
• Valves are not opened enough
• Impurities in the pipe work
• Pump draws air
• Air pockets in the suction line
• Wrong motor connection
Pump produces
• Wrong direction of rotation
low pressure
• Cavitation
• Motor is running too slow (fre-
• Wrong motor connection
Cavitation (pump
• Friction losses in suction line too
makes a cracking
noise, pump hunts
• Liquid temperature too high
on/off line)
• Liquid level in suction tank too low
Pump flow too high • Friction losses too low
Pump blocks
• Pump wrongly assembled
• Foreign body in the pump
line closed
outlet
on outlet of pump too high
quency converter)
high
guarantee full sterility and is only sensible
after a good cleaning.
• Final rinse - The final rinse has to be done
with germ-free water with a total hardness
below 5 °D (90 mg/l CaCO3). The final rinse
water is often used for pre rinse.
Solution
• Change two terminals
• Open valves
• Remove plugs
• De-aerate better
• Open all valves completely,
decrease pressure in discharge
vessel, make provisions so that
no liquid column can be built up
on the outlet of the pump, remove
any non-return valve from the
discharge pipe and, if necessary,
install it directly on the suction of
the pump.
• See above
• Change two terminals
• Open valves
• Clean pipes
• Stop leakages in suction line, raise
level in suction tank
• De-aerate
• Reconnect in the right way
• Change two terminals
• See below
• Raise frequency
• Reconnect in the right way
• All valves in suction line must be
completely open, enlarge diameters
• Cool down liquid
• Fill up tank or lower pump
• Close valve in discharge pipe
• Disassemble and assemble in the
correct way
• Clean