Installation, Operation and Maintenance Manual
VA-DC-000-1878 Rev. 0
NOTE:
The piston, control valve (20 - 10 - 310) is under spring tension and it will eventually pop
out, user beware and find means to capture the piston (20 - 10 - 310), spring (20 - 10 - 390),
washer bearing (20 - 10 - 380) and thrust bearing (20 - 10 - 370).
2.6.10 Remove flat head screw (20 - 10 - 330) from the manifold (20 - 10 - 10).
2.6.11 Remove disc, control valve (20 - 10 - 290) from the manifold (20 - 10 - 10).
2.6.12 Remove seal O-ring (20 - 20 - 40) from the manifold (20 - 10 - 10).
2.6.13 Remove seal O-ring (20 - 20 - 90) and backup ring (20 - 20 - 100) from back plate,
2.6.14 Remove seal O-ring (20 - 20 - 110) and backup ring (20 - 20 - 120) from piston,
2.6.15 Remove seal O-ring (20 - 20 - 40) and backup ring (20 - 20 - 50) from stem,
2.6.16 Remove pump rod (20 - 10 - 50) from pump cylinder (20 - 10 - 20).
2.6.17 Remove rod wiper (20 - 20 - 20), rod bushing (20 - 20 - 30) and Polypak seal
2.6.18 Remove retainer ring (20 - 10 - 80) from manifold (20 - 10 - 10).
2.6.19 Use 1/4 - 20 UNC socket cap screw (20 - 10 - 240) as provided in service kit to
2.6.20 Remove seal O-ring (20 - 20 - 40) and backup ring (20 - 20 - 50) from the pin,
2.6.21 Remove seal O-ring (20 - 20 - 60) and backup ring (20 - 20 - 70) from the pump
2.7

M18 Reservoir Disassembly

2.7.1
2.7.2
2.7.3
2.7.4
2.7.5
Actuator Disassembly
control valve (20 - 10 - 320).
control valve (20 - 10 - 310).
control valve (20 - 10 - 280).
(20 - 20 - 10) from the pump cylinder (20 - 10 - 20) bore.
remove the pin, cylinder (20 - 10 - 60) from the manifold (20 - 10 - 10). Remove
the pump cylinder (20 - 10 - 20).
cylinder (20 - 10 - 60).
cylinder (20 - 10 - 20).
Remove acorn nut (10 - 50), counter sink washer (10 - 60) and thread seal (10 - 70)
from the end cap, upper (10 - 10).
Remove end cap, bottom (10 - 40) by tapping from the open end of
center bar (10 - 30).
Remove seal O-ring (10 - 100) from the end cap, bottom (10 - 40).
Remove end cap, upper (10 - 10) from the reservoir cylinder (10 - 20).
Remove seal O-ring (10 - 100) from the end cap, upper (10 - 10).