- TEMP
:
(temperature) When NTC is connected, you can see heater's temperature in Celsius degrees. The board
has an automatic control over the led's power, so the leds are always under the safety temperature.
Go to this submenu pushing Mode , choose TEMP with + and - and push Enter to enter in. Push Mode to get out of this
function.
- MAN
: (manual mode) Function to control manually all the channels.
Go to this submenu pushing Mode , choose MAN with + and - and push Enter .
In this submenu you can choose the channel that you want to control and assign values from 0 to 255. The board run
immediately the chosen values. Dmx patch used is 13C d with 14 dmx channels and 16bit colours control, with value
from 0 to 255 for each channel.
Use COMM function to put all the channel values to zero (reset).
When the board is disconnected from Main, the manual mode is reset!!
- DEF.r
: (default reset) With this function you can restore all the default values.
Go to this submenu pushing Mode , choose DEF.r with + and - and push Enter and when the display shows "go?" push
another time Enter to confirm, push Mode if you don't want to reset.
All the values will be restored to default, except the DMX address!

DMX control mode

Default mode:
7C d
CHANNEL 1: GREEN, to control the light output of the green leds, from OFF to the Max Power.
CHANNEL 2: RED, to control the light output of the red leds, from OFF to the Max Power.
,
CHANNEL 3: BLUE
to control the light output of the blue leds, from OFF to the Max Power
,
CHANNEL 4: AMBER
to control the light output of the amber leds, from OFF to the Max Power.
CHANNEL 5: STROBE SYNC
This channel is similar to a reset, it is used to synchronized the strobe effect of more projectors.
If during strobe mode the projectors aren't flashing at the same time they have lost synchronism, use this channel to
synchronized them again.
To activate this function just modify the dmx value of this channel, then electronic board will generate one single
synchronized pulse.
Example: During the execution of one program with Sync value 0, give a different value to the channel (example 10.
The next pulse will be given when the channel will use any values different from 10 etc...)