The Simple and New Temperature Controller is Released that Easily Achieves the Temperature Control. • Easy to Read (Character Height E5CSL: 21.7 mm E5CWL: 16.2 mm (PV)). • Depth beyond front panel: Only 60 mm. • Fewer parameters for simple setup.
Setting method Digital setting using front panel keys 7-segment digital display and individual indicators Indication method Character height: E5CSL: 21.7 mm E5CWL: 16.2 mm (PV) Other functions Temperature input shift, run/stop, protection functions, etc. Ambient operating −10 to 55°C (with no icing or condensation)
E5CSL/E5CWL Input Ranges Models with Thermocouple Inputs Range Model Set value Input type (temperature input) °C °F −200 to 1,300 −300 to 2,300 −20.0 to 500.0 0.0 to 900.0 −100 to 850 −100 to 1500 −20.0 to 400.0 0.0 to 750.0 TC input −200 to 400...
Page 5
E5CSL/E5CWL Characteristics Thermocouple: (See note 1.) (±0.5% of indicated value or ±1°C, whichever is greater) ±1 digit max. Indication accuracy Platinum resistance thermometer: (±0.5% of indicated value or ±1°C, whichever is greater) ±1 digit max. Influence of temperature R and S thermocouple inputs: (±1% of PV or ±10°C, whichever is greater) ±1 digit max.
Press these keys for at least 2 seconds to start or stop operation.*2 (4) SP Lit while the set point is displayed on display No. 1 (E5CSL only). *1: These keys are disabled when starting and stopping autotuning has been disabled with operation control (5) ALM Lit while the alarm is ON.
E5CSL/E5CWL Accessories (Order Separately) Terminal Cover Front Panel E53-COV19 E53-COV20 48 × 48 43.3 Note: The E53-COV10 cannot be used. Note: 1. This Front Panel accessory is required to attach the Y92A-48B or Y92A-48D. 2. This Front Panel accessory is only the frame.
E5CSL/E5CWL Safety Precautions 9. Make sure that the rated voltage is attained within two seconds of !CAUTION turning ON the power using a switch or relay contact. If the voltage is applied gradually, the power may not be reset or output Do not touch the terminals while power is being malfunctions may occur.
Panel to cool down the Temperature Controllers. When providing forced 1. Insert the E5CSL/E5CWL into the mounting hole in the panel. cooling, however, be careful not to cool down the terminals 2. Push the adapter from the terminals up to the panel, and sections alone to avoid measurement errors.
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE...
Page 14