Kohler C3-420 Installation Instructions Manual page 8

Cleansing seat
Hide thumbs Also See for C3-420:
Table of Contents

Advertisement

Available languages

Available languages

3. Install an Electrical Outlet
GFCI/RCD-Protected
Receptacle
Supply Stop
WARNING: Risk of electric shock. Connect only to a circuit protected by a
Class A Ground-Fault Circuit-Interrupter (GFCI)*, which protects against line-
to-ground shock hazard. Use 120 V, 60 Hz, 15 A service.
*Outside North America, this may be known as a Residual Current Device (RCD).
NOTICE: Do not use an extension cord with the product.
NOTE: Follow local codes when determining the electrical outlet location.
Install a 120 V GFCI- or RCD-protected electrical outlet within 32" (813 mm) of the
toilet to accommodate the length of the power cord.
Do not plug in the seat until instructed to do so.
1354689-2-B
8