Converting The Cooktop From Nat. Gas To; Universal Lpg - Siemens EC6A5IB90A User Instructions

Table of Contents

Advertisement

Installation and connection
en
Before Leaving
Check all connections for gas leaks with soap and
water. DO NOT use a naked flame for detecting leaks.
Ignite all burners both individually and concurrently to
ensure correct operation of gas valves, burners and
ignition. Turn gas taps to low flame position and
observe stability of the flame for each burner
individually and all together. Adhere the duplicate data
plate to an accessible location near the hotplate. When
satisfied with the hotplate, please instruct the user on
the correct method of operation. In case the appliance
fails to operate correctly after all checks have been
carried out, refer to the authorised service provider in
your area.
It should be expressly noted that we cannot accept any
liability for direct or indirect damage caused by wrong
connection, leakage or improper installation. When
being repaired, the appliance must always be
disconnected from the mains supply; if required, notify
our customer service.

Converting the cooktop from Nat. Gas to

Universal LPG

All work involved in installation, setting and adaptation
to a different gas type must be carried out by a licensed
gas fitter and must comply with current regulations and
the conditions laid down by the local gas company.
Before conversion the cooktop must be disconnected
from the electricity and gas valves must be turned to the
OFF position.
Important: After finishing, stick the sticker, indicating
the new gas type, close to the specifications plate.
Replacing the injectors
Request change-over injectors from our customer
service deparment (refer injector chart below for sizes).
Natural Gas
Hourly Gas
Consumption
(MJ)
Economy
4
burner
Standard-
6.85
output
burner
High-output
11
burner
Wok burner
15
4 kW
Dual wok
19.5
burner
5 kW
8
Universal LPG
Injector
Hourly Gas
mark
Consumption
(MJ)
88
3.5
116
6
153
11
181
13
190
16.5
77
Remove all pan supports, burner caps and
1.
distributors.
To replace the injectors, use the key that is available
2.
from our technical service with code 340847 (for
double-flame burners 340808). See table. It is
important to make sure that the injector does not
become detached during removal or fastening. They
must be properly tightened to ensure that there are
no leaks.
With these burners, there is no need to adjust the
primary air.
Fasten the distributors and burner caps to the
3.
corresponding burners. In addition to this, put the
pan supports in place on the corresponding burners.
Injector
mark
50
66
87
98
96
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ec7a5rb90a

Table of Contents