Dryer Dimensions
43 ½"
(110.5 cm)
*29 ¼"
(74.3 cm)
*Most installations require a minimum 5½" (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Minimum installation spacing for recessed area or closet
installation
The dimensions shown following are for the minimum spacing
allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing of 1" (2.5 cm) on all sides of the dryer is
recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
18"
(45.7 cm)
27"
1"
1"
(68.6 cm)
(2.5 cm)
(2.5 cm)
(2.5 cm)
A
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
Mobile Home - Additional Installation Requirements
This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD Part 280) or the Canadian Manufactured
Home Standard, CAN/CSA-Z240 MH.
Mobile home installations require:
Metal exhaust system hardware which is available for
purchase from your dealer.
Mobile Home Installation Kit Part #346764. See "Tools and
Parts" section for ordering information.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
4
14 ³⁄₁₆"
(36 cm)
27"
(68.6 cm)
14" max.
2
(35.6 cm)
48 in.
2
(310 cm )
2
24 in.
2
(155 cm )
1"
29¼"
5½"
(74.3 cm)
(14 cm)
B
C
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
120-Volt, 60-Hz., AC-only, 15- or 20-amp fused electrical
supply is required. (Time-delay fuse or circuit breaker is
recommended.) It is recommended that a separate circuit
serving only this dryer be provided.
IMPORTANT: The dryer must be electrically grounded in
accordance with local codes, or in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70 or Canadian
Electrical Code, CSA C22.1.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
3"
breakdown, grounding will reduce the risk of electric shock
(7.6 cm)
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
3"
(7.6 cm)
WARNING:
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
SAVE THESE INSTRUCTIONS

Electrical Requirements

WARNING
Electrical Shock Hazard
Improper connection of the equipment-