Gas supply: Dryer is equipped for use with
NATURAL gas. Dryer can be converted to L.P. gas.
When rigid pipe is used it should be 1/2 inch IPS.
When acceptable to the gas supplier and local
codes, 3/8-inch approved tubing may be used for
lengths under 20 feet. For lengths over 20 feet,
larger tubing should be used. Pipe-joint
compounds resistant to the action of L.P. gas must
be used. If local codes permit, it is recommended
that new flexible metal tubing, design-certified by
AGA or CSA, be used for connecting the appliance
to the rigid gas supply line. (The gas pipe which
extends through the lower rear of the appliance
has 3/8-inch male pipe thread.) An individual
manual shutoff valve must be installed within 6
feet of the dryer in accordance with the National
Fuel Gas Code ANSI Z223.1.
Electrical: 120-volt, 60-Hz,
AC-only, 15- or 20-amp.
electrical supply. Use copper
wire only. A time-delay fuse
or circuit breaker and
separate circuit is
recommended.
Exhaust venting: Exhaust
your dryer to the outside.
four-inch diameter vent is
required. Rigid or flexible
metal exhaust vent must be
used. Do Not use plastic or
metal foil vent. Exhaust outlet
hood must be at least 12
inches from the ground or
any object that may be in the
path of the exhaust.
EXHAUST VENTING
Preferred
4"
4"
When you have a 4" hood
Maximum length of 4"
diameter metal vent
Number of
Rigid
Flexible
90° elbows
(fully extended)
0
64 ft.
36 ft.
1
54 ft.
31 ft.
2
44 ft.
27 ft.
3
35 ft.
25 ft.
4
27 ft.
23 ft.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Gas Dryer

OVERALL DIMENSIONS
LGR7646J
LGR8857E
LGR8858E
LGT7646E
LGW8858H
42-3/8"*
2-1/8"
* from floor with dryer feet extended 1 inch
** Most installations will require at least 5-inch clearance
behind the dryer for the dryer vent.
RECESSED AREA AND CLOSET INSTALLATION
Recessed
area
front view
48 sq. in.
18"
24 sq. in.
0"***
0"***
***Wall, door and floor molding
may require additional spacing.
Acceptable
2-1/2"
When you have a 2-1/2" hood
Maximum length of 4"
diameter metal vent
Number of
Rigid
Flexible
90° elbows
(fully extended)
0
58 ft.
28 ft.
1
48 ft.
23 ft.
2
38 ft.
19 ft.
3
29 ft.
17 ft.
4
21 ft.
15 ft.
14-1/2"
dryer exhaust
vent
6"*
9-1/4"
gas burner inlet
pipe connection
at rear of dryer
28" max.**
Closet confined area
If a closet door is installed: The minimum unobstructed
air openings are required. Louvered doors with equivalent
air openings are acceptable.
front view
3"
*
closet
door
*
3"
1"
* Minimum top and bottom air openings for closet door.
**External exhaust elbow requires additional space.
Select the route that will provide the straightest and most direct path outdoors. Plan the
installation to use the fewest number of elbows and turns. Avoid making 90° turns.
When using elbows or making turns, allow as much room as possible. Bend flexible
metal vent gradually to avoid kinking.
Determine vent length
1. See the exhaust vent length chart that matches your type hood for the maximum vent
lengths you can use.
Do not use vent runs longer than specified in exhaust vent length charts.
2. Determine the number of elbows you will need.
3. In the column listing the type of metal vent you are using (rigid or flexible), find the
maximum length of metal vent on the same line as the number of elbows.
The maximum length using a 2" x 6" rectangular vent with 2 elbows and a 2-1/2"
exhaust hood is 8 ft.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
DOOR CLEARANCE
DIMENSIONS
22-3/4"
side-swing door (reversible)
22-3/4"
29"
Large side-swing
door (reversible)
15-1/4"
Small side-swing door
side view
25-5/8"
14"
max.
4"
**
13-3/4"
Extra-large hamper door
3-7/8"
19-1/8"
22-3/4"
Super-large
7"
17-3/4"
22-3/4"
8-1/4"
15-1/4"
15-1/4"
8-3/4"
13-3/4"
Ref. 3405338 Rev. D