7. Identification of Failures and/or Particular Causes
Failure
The valves doesn't work D-dub connector not correctly
Leakage between the
valves

8. Use limitations

Do not exceed the operating conditions illustrated within either the "General Characteristics"
section of this document or in the Camozzi product catalogue.
Do not install the product in zones where the air can cause hazards.
Unless special permission has been granted do not use the product in environments where there
may be direct contact with corrosive gases, chemicals, salt water, steam or water.
Use and maintenance instruction
Valves series F
Cause
connected
Incorrect use of pin
Incorrect assembly of the valve or
terminal after the customer has
changed it
Wrong assembly of the valve Island
after replacement of a valve
93-7507-0014
Revision
Rimedio
Check the correct insertion of the D-
sub connector
Check the pin configuration and the
e electrical connection
Check the correct insertion of the
male connector on the valve with the
female connector
Check the torque force of the tie-
rods' screw