TROUBLESHOOTING
Problem
Possible Cause
Circuit breaker button is
Circuit breaker has tripped due to an
projecting from the back of the
overload.
unit.
Battery not fully charged.
The UPS does not perform
expected runtime.
Battery is worn out.
The on/off switch is designed to
prevent damage from rapidly turning
it off and on.
The unit is not connected to an AC
outlet.
The UPS will not turn on.
The battery is worn out.
Mechanical problem.
Additional troubleshooting information can be found under "Support" at
TECHNICAL SPECIFICATIONS
Serial
Model
Capacity
Nominal Input Voltage
Input Frequency
On-Battery Output Voltage
Max. Load for UPS Outlets
(5 Outlets)
Max. Load for Full-Time
Surge Protection outlets
On-Battery Output Wave
Form
Operating Temperature
Operating Relative Humidity
Size (W x H x D)
Net Weight
Battery Type
Typical Battery Recharge
Time
Typical Battery Life
3 to 6 years, depending on number of discharge/recharge cycles
Recommended Battery
Safety Approvals
UL1778(UPS), CAN/CSA C22.2 No 107.3., FCC/DoC Class B
SYSTEM FUNCTIONAL BLOCK DIAGRAM
EMI
Surge
Input
Filter
Suppressor
Normal Mode
Battery Mode
FCC Compliance Statement
FCC Compliance Statement
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help"
Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the
equipment.
Canadian Compliance Statement
CAN ICES-3 (B)/NMB-3(B)
CYBERPOWER GREENPOWER UPS™ TECHNOLOGY
Advanced Energy-Saving Patented Bypass Technology
CyberPower's patented GreenPower UPS™ with Bypass Technology reduces UPS energy costs by up to
75% compared to conventional UPS models. Even when utility power is normal, conventional UPS models
constantly pass power through a transformer. By contrast, under normal conditions the advanced circuitry
of a GreenPower UPS™ bypasses the transformer. As a result, the power efficiency is significantly
increased while decreasing waste heat, using less energy, and reducing energy costs.
When an abnormal power condition occurs, the GreenPower UPS™ automatically runs power through its
transformer to regulate voltage and provide "safe" power. Since utility power is normal over 88% of the time, the GreenPower UPS™ operates
primarily in its efficient bypass mode.
The GreenPower UPS™ is also manufactured in accordance with the Restriction on Hazardous Substances (RoHS) directive making it one of the
most environmentally-friendly on the market today.
Limited Warranty and Connected Equipment Guarantee
Please visit www.CyberPowerSystems.com for a copy of the Limited Warranty and Connected Equipment Guarantee.
Where Can I Get More Information?
The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded.
CyberPower is the warrantor under this Limited Warranty.
For further information please feel free to contact CyberPower at Cyber Power Systems (USA), Inc. 4241 12
call us at (877) 297-6937; or submit a web ticket online at cyberpowersystems.com/support.
Cyber Power Systems (USA), Inc. encourages environmentally sound methods for disposal and recycling of its UPS products.
Please dispose and/or recycle your UPS and batteries in accordance to the local regulations of your state.
All rights reserved. Reproduction without permission is prohibited.
Solution
Turn the UPS off and unplug at least one piece of
equipment. Wait 10 seconds, reset the circuit breaker by
depressing the button, and then turn the UPS on.
Recharge the battery by leaving the UPS plugged in.
Contact CyberPower Systems about replacement batteries.
Turn the UPS off. Wait 10 seconds and then turn the UPS
on.
The unit must be connected to a 120V 60Hz outlet.
Contact CyberPower Systems about replacement batteries.
Contact CyberPower Systems.
CyberPowerSystems.com
A1500SP1
CP1500AVRLCDa
1500VA / 900W
120V
60 Hz ± 3 Hz
120Vac ± 5%
1500VA / 900W
12 Amp
(12 outlets)
Simulated Sine Wave
+ 32°F to 104° F / 0° C to 40° C
0 to 90% non-condensing
3.9" x 11" x 14"
(100 x 280 x 355 mm)
25lbs / 11.3kg
CyberPower / RB1290X2
8 hours
Sealed Maintenance Free Lead Acid Battery
AVR
Output
Charger
Inverter
AC/DC
DC/A
C