Refrigerant

Take caution when handling,
DANGER
moving and using the product to
avoid damaging the refrigerant tubing or increasing
the risk of a leak
All service work shall be
WARNING
performed by factory authorized
service personnel and all component parts shall be
replaced with like components to minimize the risk of
possible ignition due to incorrect parts or improper
service.
If service is necessary, repair work
CAUTION
must be performed by a Perlick
authorized servicer. Work done by unqualified
individuals could potentially be dangerous and will
void the warranty.
This product contains blown foam
NOTICE
insulation using blowing agent
R-611 (Methyl Formate). The foam in this product
does not contain HFC's, CFC's, or HCFC's.

Preparing the Cabinet for Use

UNCRATING AND INSPECTION

Remove all crating material before operating. Carefully
inspect cabinet for hidden damage. If damage is
discovered, file your claim immediately with the transport
company. Perlick is not responsible for damage in transit.
Do not use or store flammable
DANGER
liquids (ie; gasoline) or vapors
near the appliance to avoid fire.

INSTALLATION

The unit must NOT be totally
NOTICE
enclosed or damage may occur. Air
circulation must not be restricted. The condenser at
cabinet front must be provided with a minimum of two
inches air space. Be sure to provide access so front cover
can be removed to clean the condenser.
If unit has been laid on its back or
NOTICE
sides, place unit upright and allow
a minimum of 24 hours before connecting power.
Failure to follow this procedure may damage the
compressor and void the warranty.
Use care when handling, moving
NOTICE
and using the product to avoid
damaging the refrigerant tubing or increasing the risk
of a leak.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice
FLAT TOP BOTTLE COOLERS
Operation/Installation Manual
All models covered in this user manual are manufactured
using refrigerant R290 (Propane). R290 is a hydrocarbon.
This refrigerant is flammable and is only allowed for use
in appliances which fulfill the requirements of UL 471 (To
cover potential risk originated from the use of flammable
refrigerants). Consequently, R290 is only allowed to be
used in refrigerating appliances which are designed for
this refrigerant and fulfill the above-mentioned standard.
• R290 is heavier than air. The concentration
will always be highest at floor level.
• The explosion limits are as follows:
o Lower Limit: 1.7% by vol. (37 g/m3)
o Upper Limit: 9.5% by vol. (177 g/m3)
o Ignition Temperature: 470 °C

ELECTRICAL

For specifications, see data plate located on the cabinet.
Also, see wiring diagram located in this publication.
WARNING
energizing the unit to avoid potential electric shock.
WARNING
This appliance is equipped with a 3-prong
(grounding) polarized plug for your protection
against possible shock hazards. Failure to use
grounding may result in death, serious injury, or
property damage.
WARNING
source. Do not use a two-prong adapter or remove the
power cord ground prong. Failure to use grounding
may result in death, serious injury, or property
damage.
NOTICE
damage to the unit.
5
Inspect the electrical cord and
plug for damage prior to
Use electical grounding to avoid
electrocution or electric shock.
Never use an extension cord to
connect the unit to the electrical
Using any voltage other than
specified will result in serious
Form No. Z2295
Rev. 11.19.2020