OPERATIONAL
OVERVIEW
The M9.50 batch controller features a full
graphic display and a five-button keypad for
system set-up, calibration and operation.
Full graphic display has a white backlight
during standard conditions, a red backlight
in case a set alarm is activated (OVERRUN
AND MISSING SIGNAL ALARM; always with
priority), a green backlight during the batch
perfoming. The SOURCE SOLUTION VOLUME
WARNING doesn't affect the backlight color.
The M9.50 is able to store 10 different batches
with 10 different correlated k-factors.
BATCH PERFORMING
VIEW LEVEL
(NOT RUNNING)
Volume batch
Batch volume calibration
To select batch number
Compensation value
Totalizer
Item Code - Software Release
Source solution volume in liters/
percentage
(1)
(1)
(2)
Volume Warning has been
activated.
(2)
VIEW LEVEL
(RUNNING)
Batch volume
Batch volume + flowrate
Source solution volume
in liters/percentage
Click
to start batch
Only in case Source Solution
(2)
9