Port: This is the listening port of the RFID reader. 10000 is the common port number used for this.
Debounce: This is the amount of time that a tag must be present before it begins processing. The
minimum value recommended for proper operation is 4000 milliseconds (4 seconds).
Out of Field: This is the amount of time that a tag must be out of the field of the reader before we can
assume the car has left the kiosk. The minimum value recommended for proper operation is 4000
milliseconds (4 seconds).
Blocklist Timeout: After a tag has been processed and has left the field for the Out of Field duration, the
tag is put into a blocking list to prevent that tag from being recognized again. This setting determines
how long a tag will remain in the blocking list before it can be read again.
Reset Reader: In the event the kiosk and the RFID reader appear to have stopped communicating,
clicking this button will attempt to send a command to the reader to reset and re-establish
communications.
Document #101-0243
126
02/01/18