SECTION 3
PIPER AIRCRAFT CORPORATION
EMERGENCY PROCEDURES
PA-44-180, SEMINOLE
FUEL MANAGEMENT DURING ONE ENGINE INOPERATlVE
OPERATION
CRUISING
When using fuel fr01,~ t,:nk on the same side as the operating engine:
Fuel selector operating engine ................................. ON
Fuel selector mop. engine ...................... ; . . . . . . . . . . . . . OFF
Electric fuel pumps .......................................... OFF
(except in case of engine driven pump
failure, electric fuel pump on operating
engine side must be used)
When using fuel from tank on the side opposite the operating engine:
Fuel selector operating engine ........................ CROSS FEED
Fuel selector inop. engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OFF
Electric fuel pumps .......................................•.. OFF
(except in case of engine driven pump
failure, electric fuel pump· on operating
engine side must be used)
NOTE
Use crossfeed in level cruise flight only.
LANDING
Fuel selector operating engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ON
Fuel selector inop. engine .................................... OFF
ENGINE DRIVEN FUEL PUMP FAILURE
Electric fuel pump ........................................... ON
LANDING GEAR UNSAFE WARNINGS
Red light indicates gear intransit.
Recycle gear if indication continues.
Light will illuminate and gear horn sounds when the gear is not down and
locked if throttles are at low settings or wing flaps are in second or third
notch position.
REPORT: VB-860
3-6
ISSUED: MARCH 23, 1978
REVISED: SEPTEMBER 14, 1971J