Download Print this page

Kenwood TK-3401D Service Manual page 21

Uhf digital transceiver
Hide thumbs Also See for TK-3401D:

Advertisement

*Note 2:
Only 1 DQT Balance needs to be adjusted (either DQT Balance 1 or DQT Balance 2).
*Note 3:
For the adjustment of the Maximum Deviation (dPMR Very Narrow).
After adjusting the DQT Balance and Maximum Deviation (Analog), it is necessary to adjust the Maximum Deviation (dPMR Very
Narrow).
4.7
Receiver Section
Item
1. RX Sensitivity
(1)TEST CH:
(Semiautomatic)
(2)SSG output: -90dBm (7.08uV)
AF Freq : 1kHz
*Note 4
Mod Dev : ±1.5kHz
2. RX Sensitivity
(1)TEST CH:
check
(2)SSG output: -114dBm (0.45uV)
(Analog Narrow)
AF Freq : 1kHz
Mod Dev : ±1.5kHz
3. Open Squelch 5
(1)TEST CH:
(Analog Narrow)
(2)SSG output: -120dBm (0.22uV)
AF Freq : 1kHz
Mod Dev : ±1.5kHz
3. Open Squelch 5
(1)TEST CH:
(dPMR Very Narrow)
(2)SSG output: -124dBm (0.14uV)
AF Freq : 400Hz
Mod Dev : ±1.1kHz
4. Tight squelch
(1)TEST CH:
(Analog Narrow)
(2)SSG output: -116dBm (0.35uV)
AF Freq : 1kHz
Mod Dev : ±1.5kHz
5. Low RSSI
(1)TEST CH:
(Analog Narrow)
(2)SSG output: -120dBm (0.22uV)
AF Freq : 1kHz
*Note 5
Mod Dev : ±1.5kHz
5. Low RSSI
(1)TEST CH:
(dPMR Very Narrow)
(2)SSG output: -120dBm (0.22uV)
AF Freq : 1kHz
*Note 5
Mod Dev : ±1.5kHz
6. High RSSI
(1)TEST CH:
(Analog Narrow)
(2)SSG output: -80dBm (22.4uV)
AF Freq : 1kHz
*Note 5
Mod Dev : ±1.5kHz
6. High RSSI
(1)TEST CH:
(dPMR Very Narrow)
(2)SSG output: -80dBm (22.4uV)
AF Freq : 1kHz
*Note 5
Mod Dev : ±1.5kHz
7. LBT RSSI
(1)TEST CH:
(2)SSG output: -105dBm (1.26uV)
AF Freq : 1kHz
Mod Dev : ±1.5kHz
*Note 4:
(1) Only RX Sensitivity (Semiautomatic) needs to be adjusted (RX Sensitivity does not need to be adjusted again).
*Note 5:
(1) If Analog Narrow band RSSI tuning is selected, Analog Narrow band and dPMR Very Narrow will be adjusted with the same
tuning value.
(2) If dPMR Very Narrow RSSI tuning is selected, it will adjust for the dPMR Very Narrow band only.
Condition
equipment
SSG
Oscilloscope
Audio
Analyzer
SSG
Oscilloscope
Audio
Analyzer
SSG
Oscilloscope
Audio
Analyzer
SSG
Oscilloscope
Audio
Analyzer
SSG
Oscilloscope
Audio
Analyzer
SSG
Oscilloscope
Audio
Analyzer
SSG
Oscilloscope
Audio
Analyzer
SSG
Oscilloscope
Audio
Analyzer
SSG
Oscilloscope
Audio
Analyzer
SSG
Oscilloscope
Audio
Analyzer
Measurement
Test-
Unit Terminal Unit Parts
ANT
cable
ANT
cable
ANT
cable
ANT
cable
ANT
cable
ANT
cable
ANT
cable
ANT
cable
ANT
cable
ANT
cable
Adjustment
Specifica-
tions
Method
/Remarks
FPU Press [Start]
(Auto tuning)
Check
>20dB
SINAD
FPU Press [Start]
(Auto tuning)
FPU Press [Start]
(Auto tuning)
FPU Press [Start]
(Auto tuning)
FPU Press [Start]
(Auto tuning)
FPU Press [Start]
(Auto tuning)
FPU Press [Start]
(Auto tuning)
FPU Press [Start]
(Auto tuning)
FPU Press [Start]
(Auto tuning)
(No.RA012<Rev.001>)1-21

Hide quick links:

Advertisement

loading