ATTACHMENTS, OPTIONS
The total load data for each of A to E and for all data is dis-
played on the load meter display.
Check the material selection display on load meter display (1).
In the example on the right, all of A to E for all data selected
light up.
On display (2) the total load data for all data or individual total
load data for A to E is displayed.
On display (3) the individual number of loads for A to E is dis-
played.
The total value can be cleared as follows.
1) Press the (>) or (<) of monitor panel mode selector
switch 2, and select the individual items to be cleared
from A to E or select the all lighted-up display.
2) Press the (&) of monitor panel selector switch 1 to dis-
play "RESET".
3) "YES < > NO" is displayed, and the cursor is at the NO
position, so press the (<) of monitor panel mode selector
switch 2 to move the cursor to the "Y" of YES.
4) Press the (!) of monitor panel mode selector switch 1.
The selected individual item from A to E or all the data is
cleared.
If the monitor accepts the clear command, the buzzer
gives short sounds and the display returns to the normal
service meter and time display.
HANDLING LOAD METER
6-13